2832632 Phoenix Contact, 2832632 Datasheet - Page 9
2832632
Manufacturer Part Number
2832632
Description
ETHERNET SWITCH 8 PORT RJ45
Manufacturer
Phoenix Contact
Type
Ethernetr
Specifications of 2832632
Features
8 Ports
Product
Switches
Usoc Codes
RJ45
Mounting Style
DIN Rail
Number Of Ports
8
Gender
Female
Shielding
Unshielded
Contact Type
RJ45
Number Of Rows
2
Operating Temperature Range
- 40 C to + 70 C
Current, Consumption
250 mA
Phoenix Part Number
FL SWITCH LM 8TX
Power Consumption
6 W
Voltage, Ripple
3.6 Vpp
Voltage, Supply
24 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
FL SWITCH LM 8TX
Functions/Information in Web-Based
Management
General Instructions
General description of the web pages
Device Information
–
Information about the device and manufacturer
–
The most important technical data
–
Figure showing how to connect the component
–
Explanations regarding the local status and diagnostic
indicators
–
List of transmission parameters for serial communication
General Configuration
–
Indication or modification of the current IP parameters as
well as of the addressing mechanism
–
Indication/modification of the customer-specific device
description and the trap configuration
–
Indication or modification of the parameters for the TFTP
software update
–
Specifications for saving the active configuration as well as
the option to reset the switch to the default settings
–
Modification of the current password
Switch Station
–
Status of the alarm contact and the voltage supply
–
Configuration of the states that are to be reported via a trap
© PHOENIX CONTACT 06/2007
7199_en_01
General
Technical data
Hardware installation
Local diagnostics
Serial port
IP configuration
SNMP configuration
Software update
Configuration management
Change password
Remote diagnostics
MIB2 traps
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
Phone: +49-(0) 5235-3-00 • Fax: +49-(0) 5235-3-4 12 00
www.phoenixcontact.com
–
Activation/deactivation of the SNMP agent, the web server
or RSTP
Ports
–
Activation/deactivation of individual ports
–
Individual configuration for every individual port
–
Detailed statistic information on the data volume of every
individual port
–
RS232 Communication Interface for External
Management
General function
A local communication connection for configuration
purposes can be established between the LMS and a PC
using the RS232 interface in Mini-DIN format.
You can implement the following settings in the terminal
interface:
–
–
–
–
–
–
–
Figure 4
Other services
Port table
Port configuration
Port statistics
RSTP configuration and information
Assigning the IP address
Assigning the subnet mask
Determining the default gateway
Activating/deactivating BootP
"Save Parameters" request
"Restart" request
"Reset to Factory Defaults" request
Position of the RS232 interface
8
7
6
5
U S
U S
1
2
1
2
3
4
V.24
FL SWITCH LM ...
9