XTAE007B10A001 EATON CUTLER HAMMER, XTAE007B10A001 Datasheet - Page 181
XTAE007B10A001
Manufacturer Part Number
XTAE007B10A001
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet
1.XTAE007B10A001.pdf
(240 pages)
Specifications of XTAE007B10A001
No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
1A
Overload Adjustment Current Min
0.6A
Supply Voltage Max
120VAC
Frame Size
Standard
- Current page: 181 of 240
- Download datasheet (4Mb)
Wiring Diagrams
Fuseless Installation with XTPR
Backup Protection Diagram—XTPR…B
Time/Current Curves
Characteristics
The time/current
characteristic, the current
limiting characteristics and
the I
determined in accordance
with DIN VDE 0660 and IEC
60 947.
The tripping characteristic of
the inverse-time delayed
overload releases (thermal
overload releases or “a”
releases) for DC and AC with
a frequency of 0 to 400 Hz
also apply to the time/current
characteristic.
The characteristics apply to
the cold state. At operating
temperature, the tripping
times of the thermal releases
are reduced to approximately
25%.
Under normal operating
conditions, all three-poles of
the device must be loaded.
The three main conducting
paths must be connected in
series in order to protect
single-phase or DC loads.
With three-pole loading, the
maximum deviation in the
tripping time for 3 times the
setting current and upwards
is ±20% and thus in
accordance with DIN VDE
0165.
Back-up
protection
range
with XTPAXCL
Rated
short-circuit
breaking
capacity
range
2
t characteristics were
XTPR…B
415 Vac
XTPR…B
100
50
30
20
16
10
6
XTPR...B
Inherently
short-circuit-proof
0.16...
The tripping characteristics
for the instantaneous,
electromagnetic overcurrent
releases (short-circuit
releases or “n” releases) are
based on the rated current I
which is also the maximum
value of the setting range for
circuit breakers with
adjustable overload releases.
If the current is set to a lower
value, the tripping current of
the “n” release is increased
by a corresponding factor.
The characteristics of the
electromagnetic overcurrent
releases apply to frequencies
of 50/60 Hz. Appropriate
correction factors must be
used for lower frequencies
up to 16-2/3 Hz, for higher
frequencies up to 400 Hz and
for DC.
Time/current characteristics,
current limiting characteristics
and I
available on request.
2
t characteristics are
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
1016 20 25
Rated
Current
n [A]
n
,
IEC Contactors and Starters
Backup Protection Diagram—XTPR…D
MMP Tripping Characteristics
XTPB, XTPR Frame B
XTPR Frame D
Back-up
protection
range
with XTPAXCL
Rated
short-circuit
breaking
capacity
range
200
200
2h
20
10
20
10
50
20
2h
20
10
20
10
50
20
40
40
5
2
5
5
2
5
2
5
5
2
1
2
1
1
2
1
XTPR…D
1.5 2
1.5 2
x Rated Operational Current
x Rated Operational Current
3
3
415 Vac
XTPR…D
4
4
XT IEC Power Control
XTPB, XTPR Frame B
6
6
8 10
8 10
100
XTPR Frame D
30
16
50
20
10
6
15 20
15 20
16...
XTPT
25
XTPR...D + XTPAXCL
XTPR…D
Rated
Current
30
30
n [A]
32
40
50
Rated
Current
n [A]
27.1
63
V5-T27-181
Related parts for XTAE007B10A001
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
SUB FEED LUG BLOCK 150A CUTLER HAMMER TYPE BR LOADCENTER
Manufacturer:
EATON CUTLER HAMMER
Part Number:
Description:
Handle Tie Bar For (2) - 1 Pole Type BR Breakers
Manufacturer:
EATON CUTLER HAMMER
Part Number:
Description:
Type CL Breaker 25A/1Pole 120/240V 10K-Classified 1" Ckt Bkr
Manufacturer:
EATON CUTLER HAMMER