PH100F24-12 TDK Corporation, PH100F24-12 Datasheet - Page 2

HIGH POER DC/DC CONVERTER

PH100F24-12

Manufacturer Part Number
PH100F24-12
Description
HIGH POER DC/DC CONVERTER
Manufacturer
TDK Corporation
Type
Commercialr
Datasheet

Specifications of PH100F24-12

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
18V To 36V
Power Rating
100W
Output Voltage
12V
Output Current
8.4A
Approval Bodies
CE, CSA, EN, UL
Supply Voltage
24V
Brand/series
PH-F Series
Configuration
Enclosed
Current, Rating
20 A (Max.)
Mounting Type
PCB
Number Of Outputs
1
Operation
Linear
Output
12 VDC @ 8.4 A
Power, Output
100 W
Power, Rating
100 W (Max.)
Primary Type
DC-DC Converter
Regulation, Line
20 mV (Max.)
Regulation, Load
40 mV (Max.)
Special Features
Remote On/Off, Remote Sense
Standards
UL Listed, CSA Certified an CE Marked
Temperature Coefficient
0.02%⁄°C
Temperature, Operating
-20 to +85 °C
Voltage, Input
24 VDC
Voltage, Output
12 VDC
Voltage, Output 1
12 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PH100F24-12
Manufacturer:
LAMBDA
Quantity:
37
Part Number:
PH100F24-12
Manufacturer:
LAMBDA
Quantity:
134
Part Number:
PH100F24-12
Quantity:
60
P H F e a t u r e s a n d B e n e f i t s
S p e c i f i c a t i o n s
Feature
ITEMS
Input range
Output Voltage Adj. Range
Line Regulation
Load Regulation
Ripple and Noise
Series Operation
Over Voltage Protection
Overload Protection
Remote On/Off
Remote Sensing
Parallel operation
Inverter Good signal
Auxiliary Bias Supply
Thermal Protection
Cooling
Operating Temperature Range
Storage Temperature
Temperature Coefficient
Isolation
Isolation Resistance
Safety Agency Approval
Warranty
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) 24V input models input to output: 2kVAC; input to baseplate: 2kVAC
Low component count
Wide output adjustment
Signals to support N+1 redundancy
Variety of input voltages
pk-pk
VDC
VDC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.6~2.4
Using current share pin (PC). Will share within 5%, see app. notes for connection details
0.8% or 40mV (whichever is greater) from no load to full load with constant input line
Conduction or forced air. See application notes for cooling and heatsink selection
2V
24V nom: 18-36, 48V nom: 36-76V, 110V nom: 82-185V, 280V nom: 200-400V
Baseplate temperature -20°C to +85°C. -40°C start up possible - consult factory
Possible - Refer to installation manual
0.4% or 20mV (whichever is greater) over entire input range with constant load
150 - 180%
8V 10mA auxiliary voltage to supply power to interface circuits (AUX pin)
2.64~3.96
Input to output: 3000VAC, Input to Baseplate: 2500VAC(1)
100mV
Output to Baseplate -100MOhm at 500VDC and 70%RH
3.3V
UL60950-1, CSA60950-1, EN60950-1 and CE Mark.
Full function, 50 to 300W DC-DC converters
PH-F Series
Approximately 105 - 140%, automatic recovery
Signal available for status of inverter
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Telecom
Custom Power Supplies
N+1 redundant systems
Scalable systems
Point of Load
2~6
High Density
Wide Range Input
Wide output adjustment capability
Remote On/Off
Fixed Switching Frequency
International Safety Approvals
Parallel Operation
Internal sensing, self resetting
5V
Benefit
Low = ON, Open = OFF
High reliability demonstrated 5 million hours MTBF
Avoids the need for custom modules
Ease of use in redundant configurations
Systems can operate from different input voltages
-40°C to +85°C
4.8~14.4
0.02%/°C
Two years
12V
Yes
150mV
125 - 145%
6~18
15V
9.6~28.8
240mV
24V
11.2~33.6
280mV
28V
139

Related parts for PH100F24-12