ICS512M IDT, Integrated Device Technology Inc, ICS512M Datasheet - Page 4

no-image

ICS512M

Manufacturer Part Number
ICS512M
Description
IC PLL CLOCK MULTIPLIER 8-SOIC
Manufacturer
IDT, Integrated Device Technology Inc
Series
LOCO™r
Type
Clock Generatorr
Datasheet

Specifications of ICS512M

Pll
Yes with Bypass
Input
Clock, Crystal
Output
CMOS
Number Of Circuits
1
Ratio - Input:output
1:2
Differential - Input:output
No/No
Frequency - Max
200MHz
Divider/multiplier
No/Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
8-SOIC
Frequency-max
200MHz
Number Of Elements
1
Supply Current
9mA
Pll Input Freq (min)
2MHz
Pll Input Freq (max)
50MHz
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
0C to 70C
Package Type
SOIC N
Output Frequency Range
14 to 200MHz
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
5V
Operating Temperature Classification
Commercial
Pin Count
8
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
512M

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICS512M
Quantity:
5 510
Part Number:
ICS512M
Manufacturer:
ICS
Quantity:
1 900
Part Number:
ICS512M
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS512M-1
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS512M-2
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS512MLF
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS512MLFT
Manufacturer:
IDT
Quantity:
20 000
IDT™ / ICS™ LOCO™ PLL CLOCK MULTIPLIER
ICS512
LOCO™ PLL CLOCK MULTIPLIER
External Components
Decoupling Capacitor
As with any high-performance mixed-signal IC, the
ICS512 must be isolated from system power supply
noise to perform optimally.
A decoupling capacitor of 0.01µF must be connected
between VDD and GND. It must be connected close to
the ICS512 to minimize lead inductance. No external
power supply filtering is required for the ICS512.
Series Termination Resistor
A 33 terminating resistor can be used next to the CLK
pin. The total on-chip capacitance is approximately 12
pF. A parallel resonant, fundamental mode crystal
should be used.
Absolute Maximum Ratings
Recommended Operation Conditions
Stresses above the ratings listed below can cause permanent damage to the ICS512. These ratings, which
are standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the
device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature (commercial)
Ambient Operating Temperature (industrial)
Storage Temperature
Soldering Temperature
Parameter
Ambient Operating Temperature (commercial)
Ambient Operating Temperature (industrial)
Power Supply Voltage (measured in respect to GND)
Item
4
Crystal Load Capacitors
The device crystal connections should include pads for
small capacitors from X1 to ground and from X2 to
ground. These capacitors are used to adjust the stray
capacitance of the board to match the nominally
required crystal load capacitance. Because load
capacitance can only be increased in this trimming
process, it is important to keep stray capacitance to a
minimum by using very short PCB traces (and no vias)
between the crystal and device. Crystal capacitors, if
needed, must be connected from each of the pins X1
and X2 to ground.
The value (in pF) of these crystal caps should equal (C
-12 pF)*2. In this equation, C
in pF. Example: For a crystal with a 16 pF load
capacitance, each crystal capacitor would be 8 pF
[(16-12) x 2] = 8.
Min.
+3.0
-40
0
7 V
-0.5 V to VDD+0.5 V
0 to +70 C
-40 to +85 C
-65 to +150 C
260 C
Typ.
L
Rating
= crystal load capacitance
Max.
+5.0
+70
+85
ICS512
CLOCK MULTIPLIER
Units
REV H 051310
V
C
C
L

Related parts for ICS512M