OP290_03 AD [Analog Devices], OP290_03 Datasheet
OP290_03
Related parts for OP290_03
OP290_03 Summary of contents
Page 1
FEATURES Single-/Dual-Supply Operation True Single-Supply Operation; Input and Output Voltage Ranges Include Ground Low Supply Current (Per Amplifier Max High Output Drive Min Low Input ...
Page 2
OP290–SPECIFICATIONS ELECTRICAL CHARACTERISTICS Parameter Symbol INPUT OFFSET VOLTAGE V OS INPUT OFFSET CURRENT I OS INPUT BIAS CURRENT I B LARGE-SIGNAL A VO VOLTAGE GAIN 1 INPUT VOLTAGE RANGE IVR OUTPUT VOLTAGE SWING COMMON-MODE CMR REJECTION ...
Page 3
ELECTRICAL CHARACTERISTICS Parameter INPUT OFFSET VOLTAGE AVERAGE INPUT OFFSET VOLTAGE DRIFT INPUT OFFSET CURRENT INPUT BIAS CURRENT LARGE-SIGNAL VOLTAGE GAIN INPUT VOLTAGE RANGE * OUTPUT VOLTAGE SWING COMMON-MODE REJECTION POWER SUPPLY REJECTION RATIO SUPPLY CURRENT (All Amplifiers) Guaranteed by CMR ...
Page 4
OP290 1 ABSOLUTE MAXIMUM RATINGS Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± ...
Page 5
V = 15V –75 –50 – 100 125 TEMPERATURE – C TPC 1. Input Offset Voltage vs. Temperature 44 NO LOAD 15V S ...
Page 6
OP290 140 NEGATIVE SUPPLY 120 100 POSITIVE SUPPLY 100 1k FREQUENCY – Hz TPC 10. Power Supply Rejection vs. Frequency 15V S ...
Page 7
OP290 3 200 6 1/2 OP290 5 100k 4 –18V Figure 2. Burn-In Circuit APPLICATIONS INFORMATION BATTERY-POWERED APPLICATIONS The OP290 can be operated on a minimum supply voltage of 1 with dual supplies ...
Page 8
OP290 From the formulas, it can be seen that if the span trim is adjusted before the zero trim, the two trims are not interactive, which greatly simplifies the calibration procedure. Calibration of the transmitter is simple. First, the slope ...
Page 9
250k C1 1/2 0.1 F OP290GP 25k 6 1/2 OP290GP 5 4 –15V DIODES ARE 1N4148 Figure 6. Variable Slew Rate Filter LOW OVERHEAD VOLTAGE REFERENCE Figure 7 shows a ...
Page 10
OP290 0.150 (3.81) 0.130 (3.30) 0.110 (2.79) 0.022 (0.56) 0.018 (0.46) 0.014 (0.36) CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS (IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN OUTLINE DIMENSIONS 8-Lead ...
Page 11
Revision History Location 12/03—Data Sheet changed from REV REV. B. Deleted OP290E and OP290F . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 12
–12– ...