D12321VF25V Renesas Electronics America, D12321VF25V Datasheet - Page 645

IC H8S/2300 MCU ROMLESS 128QFP

D12321VF25V

Manufacturer Part Number
D12321VF25V
Description
IC H8S/2300 MCU ROMLESS 128QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12321VF25V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
86
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
128-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12321VF25V
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
D12321VF25V
Manufacturer:
Renesas
Quantity:
675
Part Number:
D12321VF25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Bit 4—Framing Error (FER): Indicates that a framing error occurred during reception in
asynchronous mode, causing abnormal termination.
Bit 4
FER
0
1
Notes: 1. The FER flag is not affected and retains its previous state when the RE bit in SCR is
Bit 3—Parity Error (PER): Indicates that a parity error occurred during reception using parity
addition in asynchronous mode, causing abnormal termination.
Bit 3
PER
0
1
Notes: 1. The PER flag is not affected and retains its previous state when the RE bit in SCR is
2. In 2-stop-bit mode, only the first stop bit is checked for a value of 0; the second stop bit
2. If a parity error occurs, the receive data is transferred to RDR but the RDRF flag is not
cleared to 0.
is not checked. If a framing error occurs, the receive data is transferred to RDR but the
RDRF flag is not set. Also, subsequent serial reception cannot be continued while the
FER flag is set to 1. In synchronous mode, serial transmission cannot be continued,
either.
cleared to 0.
set. Also, subsequent serial reception cannot be continued while the PER flag is set to
1. In synchronous mode, serial transmission cannot be continued, either.
Description
[Clearing condition]
When 0 is written to FER after reading FER = 1
[Setting condition]
When the SCI checks the stop bit at the end of the receive data when reception ends,
and the stop bit is 0 *
Description
[Clearing condition]
When 0 is written to PER after reading PER = 1
[Setting condition]
When, in reception, the number of 1 bits in the receive data plus the parity bit does not
match the parity setting (even or odd) specified by the O/E bit in SMR *
2
Section 14 Serial Communication Interface (SCI)
Rev.6.00 Sep. 27, 2007 Page 613 of 1268
REJ09B0220-0600
2
(Initial value) *
(Initial value) *
1
1

Related parts for D12321VF25V