MPC562MZP56 Freescale Semiconductor, MPC562MZP56 Datasheet - Page 1035

IC MPU 32BIT 56MHZ PPC 388-PBGA

MPC562MZP56

Manufacturer Part Number
MPC562MZP56
Description
IC MPU 32BIT 56MHZ PPC 388-PBGA
Manufacturer
Freescale Semiconductor
Series
MPC5xxr
Datasheet

Specifications of MPC562MZP56

Core Processor
PowerPC
Core Size
32-Bit
Speed
56MHz
Connectivity
CAN, EBI/EMI, SCI, SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
64
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
2.5 V ~ 2.7 V
Data Converters
A/D 32x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 125°C
Package / Case
388-BGA
Processor Series
MPC5xx
Core
PowerPC
Data Bus Width
32 bit
Data Ram Size
8 KB
Interface Type
SCI, SPI, UART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
56
Number Of Timers
22
Operating Supply Voltage
2.6 V to 5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
2 (10 bit, 32 Channel)
For Use With
MPC564EVB - KIT EVAL FOR MPC561/562/563/564
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC562MZP56
Manufacturer:
FREESCAL
Quantity:
204
Part Number:
MPC562MZP56
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MPC562MZP56
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MPC562MZP56
Manufacturer:
FREESCALE
Quantity:
7 699
Company:
Part Number:
MPC562MZP56
Quantity:
1 500
Part Number:
MPC562MZP56R2
Manufacturer:
RFT
Quantity:
1 441
Part Number:
MPC562MZP56R2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
The error message has the following format:
24.10.8.2 Invalid Message
An error message is sent out when an invalid message is received by READI. The error code within the
error message indicates that an invalid TCODE was detected in the auxiliary input messages by the signal
input formatter. Refer to
The error message has the following format:
If the TCODE is valid, then READI will expect that the correct number of packets have been received and
no further checking will be performed. If the number of packets received by READI is not correct, READI
response is not deterministic.
24.10.8.3 Invalid Access Opcode
An error message is sent out when an invalid access opcode is received by READI. The error code within
the error message indicates that an invalid access opcode was detected in the auxiliary input messages by
the signal input formatter. Refer to
The error message has the following format:
24.10.9 Faster Read/Write Accesses with Default Attributes
Read/write access throughput may be increased by taking advantage of the default settings of the RWA
register, and truncating the least significant zero bits of the download request message. For example, to
read a word from the default memory map, with default attributes, a download request message that selects
Freescale Semiconductor
Figure 24-60. Error Message (Read/Write Access Error) Format
Figure 24-62. Error Message (Invalid Access Opcode) Format
Table
Figure 24-61. Error Message (Invalid Message) Format
TCODE (8)
TCODE (8)
TCODE (8)
24-20.
[6 bits]
[6 bits]
[6 bits]
MPC561/MPC563 Reference Manual, Rev. 1.2
Table
Length = 11 bits
Length = 11 bits
Length = 11 bits
24-20.
Error Code (0b00011)
Error Code (0b00100)
Error Code (0b00101)
NOTE
[5 bits]
[5 bits]
[5 bits]
READI Module
24-67

Related parts for MPC562MZP56