HD64F3684FP Renesas Electronics America, HD64F3684FP Datasheet - Page 375

IC H8 MCU FLASH 32K 64LQFP

HD64F3684FP

Manufacturer Part Number
HD64F3684FP
Description
IC H8 MCU FLASH 32K 64LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3684FP

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
45
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3684FPI
Quantity:
2 761
Part Number:
HD64F3684FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3684FPV
Manufacturer:
RENESAS
Quantity:
28
Part Number:
HD64F3684FPV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
18.3.2
ADCSR consists of the control bits and conversion end status bits of the A/D converter.
Bit
7
6
5
4
3
Bit Name
ADF
ADIE
ADST
SCAN
CKS
A/D Control/Status Register (ADCSR)
Initial
Value
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
Description
A/D End Flag
[Setting conditions]
[Clearing condition]
A/D Interrupt Enable
A/D conversion end interrupt request (ADI) is enabled by
ADF when this bit is set to 1
A/D Start
Setting this bit to 1 starts A/D conversion. In single mode,
this bit is cleared to 0 automatically when conversion on
the specified channel is complete. In scan mode,
conversion continues sequentially on the specified
channels until this bit is cleared to 0 by software, a reset,
or a transition to standby mode.
Scan Mode
Selects single mode or scan mode as the A/D conversion
operating mode.
0: Single mode
1: Scan mode
Clock Select
Selects the A/D conversions time.
0: Conversion time = 134 states (max.)
1: Conversion time = 70 states (max.)
Clear the ADST bit to 0 before switching the conversion
time.
When A/D conversion ends in single mode
When A/D conversion ends once on all the channels
selected in scan mode
When 0 is written after reading ADF = 1
Rev.5.00 Nov. 02, 2005 Page 341 of 500
Section 18 A/D Converter
REJ09B0027-0500

Related parts for HD64F3684FP