R5S72030W200FP Renesas Electronics America, R5S72030W200FP Datasheet - Page 1065

IC SUPERH MPU ROMLESS 240QFP

R5S72030W200FP

Manufacturer Part Number
R5S72030W200FP
Description
IC SUPERH MPU ROMLESS 240QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7200r
Datasheets

Specifications of R5S72030W200FP

Core Processor
SH2A-FPU
Core Size
32-Bit
Speed
200MHz
Connectivity
CAN, I²C, SCI, SSI, SSU, USB
Peripherals
DMA, LCD, POR, PWM, WDT
Number Of I /o
82
Program Memory Type
ROMless
Ram Size
80K x 8
Voltage - Supply (vcc/vdd)
1.1 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
240-QFP
For Use With
R0K572030S000BE - KIT DEV FOR SH7203HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5S72030W200FP
Manufacturer:
SAMSUNG
Quantity:
1 001
Part Number:
R5S72030W200FP
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
R5S72030W200FP
Manufacturer:
RENESAS
Quantity:
8 000
20.4.3
Scan mode is useful for monitoring analog inputs in a group of one or more channels at all times.
In scan mode, A/D conversion is performed sequentially for a maximum of eight specified analog
input channels, as follows:
1. A/D conversion starts from the analog input channel with the lowest number (e.g. AN0, AN1,
2. When A/D conversion is completed on each channel, the A/D conversion result is sequentially
3. After A/D conversion on all selected channels has completed, the ADF bit in ADCSR is set to
4. The ADST bit is not cleared automatically, so steps 2. and 3. are repeated as long as the ADST
When the operating mode or analog input channel selection must be changed during A/D
conversion, to prevent incorrect operation, first clear the ADST bit to 0 to halt A/D conversion.
After making the necessary changes, set the ADST bit to 1. A/D conversion will start again from
the first channel in the group. The ADST bit can be set at the same time as the mode or channel
selection is changed.
Typical operations when three channels (AN0 to AN2) are selected in scan mode are described as
follows. Figure 20.4 shows a timing diagram for this example.
1. Scan mode is selected (MDS2 = 1, MDS1 = 1), analog input channels AN0 to AN2 are
2. A/D conversion of the first channel (AN0) starts. When A/D conversion is completed, the A/D
3. Next, the second channel (AN1) is selected automatically and A/D conversion starts.
4. Conversion proceeds in the same way through the third channel (AN2).
5. When conversion of all the selected channels (AN0 to AN2) is completed, the ADF flag is set
…, AN3) when the ADST bit in ADCSR is set to 1 by software, MTU2, or external trigger
input.
transferred to the A/D data register corresponding to that channel.
1. If the ADIE bit is set to 1 at this time, an ADI interrupt request is generated. The A/D
converter starts A/D conversion again from the channel with the lowest number.
bit remains set to 1. When the ADST bit is cleared to 0, A/D conversion halts and the A/D
converter becomes idle.
The ADF bit is cleared by reading ADF while ADF = 1, then writing 0 to the ADF bit.
selected (CH[2:0] = 010), and A/D conversion is started (ADST = 1).
conversion result is transferred into ADDRA.
to 1 and conversion of the first channel (AN0) starts again. If the ADIE bit is set to 1 at this
time, an ADI interrupt is requested.
Scan Mode
Rev. 3.00 Sep. 28, 2009 Page 1033 of 1650
Section 20 A/D Converter (ADC)
REJ09B0313-0300