Specifications of R5S72030W200FP

Core Processor
SH2A-FPU
Core Size
32-Bit
Speed
200MHz
Connectivity
CAN, I²C, SCI, SSI, SSU, USB
Peripherals
DMA, LCD, POR, PWM, WDT
Number Of I /o
82
Program Memory Type
ROMless
Ram Size
80K x 8
Voltage - Supply (vcc/vdd)
1.1 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
240-QFP
For Use With
R0K572030S000BE - KIT DEV FOR SH7203HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5S72030W200FP
Manufacturer:
SAMSUNG
Quantity:
1 001
Part Number:
R5S72030W200FP
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
R5S72030W200FP
Manufacturer:
RENESAS
Quantity:
8 000
Section 23 USB 2.0 Host/Function Module (USB)
23.4.9
When the function controller function is selected and if data could not be received at intervals of 1
ms (when using full-speed operation) or 125 μs (when using high-speed operation) because an
SOF packet was corrupted or missing, this module interpolates the SOF. The SOF interpolation
operation begins when USBE = 1, SCKE = 1 and an SOF packet is received. The interpolation
function is initialized under the following conditions.
• Power-on reset
• Software reset
• USB bus reset
• Suspended state detected
Also, the SOF interpolation operates under the following specifications.
• 125 μs/1 ms conforms to the results of the reset handshake protocol.
• The interpolation function is not activated until an SOF packet is received.
• After the first SOF packet is received, either 125 μs or 1 ms is counted with the USB clock of
• After the second and subsequent SOF packets are received, interpolation is carried out at the
• Interpolation is not carried out in the suspended state or while a USB bus reset is being
Rev. 3.00 Sep. 28, 2009 Page 1226 of 1650
REJ09B0313-0300
Normal transfer
Token corrupted
Packet inserted
Frame misaligned
Frame misaligned
Token delayed
48 MHz, and interpolation is carried out.
previous reception interval.
received. (With suspended transitions in high-speed operation, interpolation continues for 3 ms
after the last packet is received.)
SOF
Figure 23.19 Example of an Interval Error Being Generated when IITV = 1
SOF Interpolation Function
Token
Token
Token
Token
Token
Token
Token
Token
Token
1
1
1
Token
Token
Token
Token
Token
Token
Token
Token
1
1
Token
Token
Token
Token
Token
Token
1
1