MAX834EUK+T Maxim Integrated Products, MAX834EUK+T Datasheet - Page 7

IC MONITOR VOLT LATCH SOT23-5

MAX834EUK+T

Manufacturer Part Number
MAX834EUK+T
Description
IC MONITOR VOLT LATCH SOT23-5
Manufacturer
Maxim Integrated Products
Type
Simple Reset/Power-On Resetr
Datasheet

Specifications of MAX834EUK+T

Number Of Voltages Monitored
1
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
80 µs Typical Propagation Delay
Voltage - Threshold
Adjustable/Selectable
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
SOT-23-5, SC-74A, SOT-25
Undervoltage Threshold
1.185 V
Overvoltage Threshold
1.215 V
Manual Reset
No
Watchdog
No
Supply Voltage (max)
11 V
Supply Voltage (min)
2.5 V
Supply Current (typ)
5 uA
Maximum Power Dissipation
571 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MAX834EUK+T
MAX834EUK+TTR
Figure 4. Monitoring Voltages Other than V
Figure 5. Load-Disconnect Switch
V
*MAX834 ONLY
BATT
V
CC
V
CC
R1
CLEAR
LATCH
LATCH
CLEAR
0.1μF
0.1μF
_______________________________________________________________________________________
GND
V
CLEAR
CC
Micropower, Latching Voltage Monitors
GND
V
CLEAR
MAX835
CC
MAX834
MAX835
V
(UNITS ARE OHMS AND VOLTS)
OUT
TRIP
IN
OUT
= (1.204)
IN
R1 + R2
1MΩ
Q2
R2
V
CC
R2
CC
Q1
R
L
*
OUT
P
N
V
MON
R
R1
R2
LOAD
The Typical Operating Circuit for the MAX834/MAX835
monitors V
monitored, as shown in Figure 4. Calculate V
the Programming the Trip Voltage (V
When monitoring voltages other than V
the maximum value for V
The circuit in Figure 5 is designed to prevent a lead-
acid battery or a secondary battery such as an NiCd,
from sustaining damage through deep discharge. As
the battery reaches critical undervoltage, OUT switches
low. Q1 and Q2 turn off, disconnecting the battery from
the load. The MAX835’s latched output prevents Q1
and Q2 from turning on again as the battery voltage
relaxes to its open-circuit voltage when the load dis-
connects. CLEAR can be connected to a pushbutton
switch, an RC network, or a logic gate to reset the latch
when the battery is recharged or replaced.
Monitoring Voltages Other than V
V
MON(MAX)
CC
. Voltages other than V
= (V
Load-Disconnect Switch
MON
CC
- 1) (R1 + R2) / R2
in SOT23-5
is not exceeded:
CC
CC
TRIP
can easily be
, ensure that
) section.
TRIP
as in
CC
7

Related parts for MAX834EUK+T