... Thermal Cutoffs (TCO)/ Thermal-links EYP N Series: F Series: E Series: H Series: MP Series: MU Series: ■ Features ● Small and Insulation Type TCO is compact and insulated, featuring quick temperature response, and mountable in a small space without insulation or protection. ● High Reliability TCO opens reliably when the equipment becomes abnormal, and is not resettable. ...
Page 2
... F series Type No. of Rated Approved Functioning Part No. ✽1 Standards Temp (°C) EYP1BF101 F101 102 EYP1BF115 F115 115 EYP1BF134 F134 134 EYP1BF138 F138 139 EYP1BF145 F145 145 Note: (1) For long lead types add the letter “L” at the end op the part number. ...
Page 3
... H series Type No. of Rated Approved Functioning Part No. ✽1 Standards Temp (°C) EYP2BH101 H101 102 EYP2BH115 H115 115 EYP2BH134 H134 134 EYP2BH138 H138 139 EYP2BH145 H145 145 Note: (1) The information of the Approved Safety Standards is furnished as of Jun. 2010. Approved Safety Standards File No. UL/C-UL:E60271, CSA:1709435(LR67163), VDE:481106-1171-0004, BEAB:C1140, CCC:2002010205004245 Design and specifi ...
Page 4
... Functioning Temp. Part No. ✽1 Temp (°C) (°C) EYP4MU092GFD 92 89 Note: (1) The information of the Approved Safety Standards is furnished as of Jun. 2010. Approved Safety Standards File No. UL:E60271 ✽1 Rated Functioning Temperature (Tf) The temperature at which a TCO changes its state of conductivity to open circuit with loading detection current only. ...
Page 5
... EYP1BF EYP1BF L EYP05BE EYP05BE L EYP2BH EYP2MP AFT EYP4MU GFD Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. ...
Page 6
Safety Precautions (Handling Precautions) The following are precautions for individual products. Please also refer to the common precautions shown on page 4 of this catalog. ● Design Applications 1. Use the TCO within their specifi ed temperature and electrical ratings. ...
Page 7
Bending > > Soldering, Welding, Calking 1) Lead wires are to be soldered with the standard conditions shown in Table 1. Excessive soldering heat and soldering time may cause damage to a TCO. If higher ...