TDA5150 Infineon Technologies, TDA5150 Datasheet - Page 63

IC TX MULTI-CH/BAND 10-TSSOP

TDA5150

Manufacturer Part Number
TDA5150
Description
IC TX MULTI-CH/BAND 10-TSSOP
Manufacturer
Infineon Technologies
Type
Multiband Transmitterr
Datasheet

Specifications of TDA5150

Package / Case
10-TSSOP
Frequency
300MHz ~ 320MHz, 425MHz ~ 450MHz, 863MHz ~ 928MHz
Applications
RKE, Security Systems
Modulation Or Protocol
ASK, FSK, GFSK
Data Rate - Maximum
50 kbps
Power - Output
10dBm
Current - Transmitting
16mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
1.9 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Supply Current
16 mA
Supply Voltage (max)
3.6 V
Supply Voltage (min)
1.9 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
SP000300415
TDA5150
TDA5150INTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA5150
Manufacturer:
AD
Quantity:
450
Company:
Part Number:
TDA5150
Quantity:
4 800
Part Number:
TDA5150HTMA1
0
2.4.11.3 Channel Hopping
TDA 5150 offers the possibility for usage of up to 4 preconfigured RF channels, called
A, B, C, and D frequency channels. The preconfiguration assumes proper programming
PLL’s Multi-Modulus Integer Value registers A/B/C/D
PLL Fractional Division Ratio registers A/B/C/D
(0x0A:0x0C/0x0E:0x10/0x12:0x14/0x16:0x18.
used for frequency channel selection. Thus it is possible to quickly switch between RF
frequency channels, without reconfiguration (assuming channels A...D have been
preconfigured in advance).
Any frequency hop inside the band requires a new Transmit Command and100 µs idle
time for the PLL to perform the VCO Auto Calibration and to settle (achieve locked state).
For frequency hops to frequencies not more than 1 MHz apart from the frequency on
which the VCO Auto Calibration was performed, it is possible to skip the VCO Auto
Calibration and thus to reduce the PLL settling time to 20µs instead of 100µs. In this case
it is allowed to start the transmission, triggered by a rising edge on the SCK line, by
waiting for only 20 µs after the Transmit Command was completed.
The VCO Auto Calibration can be skipped by setting the bit FHBLANK
GFXOSC
There should be no more than 4 consecutive jumps without VCO Auto Calibration during
transmissions.
If bit B of the Transmit Command is set, the PA will stay active, until the time-out
condition is reached (i.e. for a duration of 65536 / f
MHz reference clock)
2.4.11.4 SFRs related to Channel Hopping
FHBLANK
Data Sheet
ADDR 0x1E
FHBLANK
Bit 7
Bit 7
w/0
(0x1E)
FHBLANK
reserved
Bit 6
w/1
to 1.
Frequency Hopping, enable/disable VCO Auto Calibration for Channel Hopping
GFXOSC—Gaussian Filter Configuration
0: enable VCO Auto Calibration
(default)
reserved
Bit 5
w/1
reserved
Bit 4
w/1
63
Frequency Hopping VAC Disable
GFBYP
Bit 3
w/1
Bit-filed <E:F> in Transmit Command is
sys
TDA 5150 Functional Description
(0x09/0x0D/0x11/0x15)
1: Skip VCO Auto Calibration for
frequency hops <1MHz
corresponding to ~5 ms for a 13
GFDIV
Bit 2
w/0
GFDIV
Bit 1
w/0
(0x1E.7)
V 1.0, July 2009
TDA 5150
and the
GFDIV
Bit 0
w/0
in SFR

Related parts for TDA5150