3030AN Honeywell Sensing and Control, 3030AN Datasheet

SENSOR VRS 5/8" HIGH OUT 190V

3030AN

Manufacturer Part Number
3030AN
Description
SENSOR VRS 5/8" HIGH OUT 190V
Manufacturer
Honeywell Sensing and Control
Series
3030r
Type
VRS (Passive)r
Datasheets

Specifications of 3030AN

Output Type
Sine Wave
Actuator Material
Ferrous Metals, Gear Tooth
Termination Style
Connector
Frequency
15kHz
Must Operate
*
Must Release
*
Function
*
Package / Case
Barrel, Stainless Steel
Sensor Housing
Cylindrical
Peak Reflow Compatible (260 C)
No
Output Voltage
60V
Sensor Terminals
Wire Leads
Leaded Process Compatible
No
Features
Mounting Thread
Weight
2.5oz
Lead Free Status / RoHS Status
Lead free by exemption / RoHS non-compliant
Voltage - Supply
-
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free by exemption / RoHS non-compliant
Other names
.3030AN
480-2776
High Output
Industrial VRS Magnetic
Speed Sensors
DESCRIPTION
High Output VRS sensors are designed for use in applications
where higher output voltages are needed. They perform best at
low to medium speeds with medium to high impedance loads.
Front-End Sealed versions are available for use where the
sensor is exposed to fluids, lubricants or adverse
environmental conditions.
Passive VRS (Variable Reluctance Speed) Magnetic Speed
sensors are simple, rugged devices that do not require an
external voltage source for operation.
A permanent magnet in the sensor establishes a fixed
magnetic field. The approach and passing of a ferrous metal
target near the sensor’s pole piece (sensing area) changes the
flux lines of the magnetic field, dynamically changing its
strength. This change in magnetic field strength induces a
current into a coil winding which is attached to the output
terminals.
FEATURES
Self-powered operation
Direct conversion of actuator speed to output frequency
Simple installation
No moving parts
Designed for use over a wide range of speeds
Adaptable to a wide variety of configurations
Customized VRS products for unique speed sensing
applications
Housing diameters: 5/8 in (M16), 3/8 in (M12)
Housing materials/styles: stainless steel threaded or
smooth
Terminations: MS3106 connector, preleaded
Output voltages: 8 Vp-p to 190 Vp-p
The output signal of a VRS sensor is an ac voltage that varies
in amplitude and wave frequency as the speed of the
monitored device changes, and is usually expressed in peak to
peak voltage (Vp-p).
One complete waveform (cycle) occurs as each target passes
the sensor’s pole piece. If a standard gear were used as a
target, this output signal would resemble a sine wave if viewed
on an oscilloscope.
Honeywell also offers VRS sensors for general purpose, power
output, high resolution, high temperature, and hazardous
location applications, as well as low-cost molded versions.
POTENTIAL APPLICATIONS
Engine RPM (revolutions per minute) measurement on
aircraft, automobiles, boats, buses, trucks and rail
vehicles
Motor RPM measurement on drills, grinders, lathes and
automatic screw machines
Motor RPM measurement on precision camera, tape
recording and motion picture equipment
Process speed measurement on food, textile, paper,
woodworking, printing, tobacco and pharmaceutical
industry machinery
Motor speed measurement of electrical generating
equipment
Speed measurement of pumps, blowers, mixers, exhaust
and ventilating fans
Flow measurement on turbine meters
Wheel-slip measurement on autos and locomotives
Gear speed measurement

Related parts for 3030AN

3030AN Summary of contents

Page 1

High Output Industrial VRS Magnetic Speed Sensors DESCRIPTION High Output VRS sensors are designed for use in applications where higher output voltages are needed. They perform best at low to medium speeds with medium to high impedance loads. Front-End Sealed ...

Page 2

... General Specifications Parameter Characteristic Min. output voltage 190 Vp-p Coil resistance 910 Ohm to 1200 Ohm Pole piece 2,69 mm [0.106 in] diameter Min ...

Page 3

... Surface speed 25 m/s [1000 in/s] Gear 20 DP (module 1.27) Air gap 0,127 mm [0.005 in] Load 100 kOhm resistance Test Condition Specifications Parameter Characteristic Surface speed 25 m/s [1000 in/s] Gear 20 DP (module 1.27) Air gap 0,127 mm [0.005 in] Load 100 kOhm resistance Honeywell Sensing and Control 3 ...

Page 4

High Output 5/8 INCH (M16*) SEALED FRONT-END SENSORS (All dimensions for reference only. mm/[in]) *Contact Honeywell for availability of metric mounting thread versions. HIGH RESISTANCE COILS FOR MAXIMUM OUTPUT VOLTAGE APPLICATIONS General Specifications Parameter Characteristic Min. output 175 Vp-p voltage ...

Page 5

... N/A actuator Maximum 40 kHz typ. operating frequency Vibration Mil-Std 202F Method 204D Termination MS3106 connector Test Condition Specifications Parameter Characteristic Surface speed 25 m/s [1000 in/s] Gear 8 DP (module 3.17) Air gap 0,127 mm [0.005 in] Load 1.25 kOhm resistance Honeywell Sensing and Control 5 ...

Page 6

High Output 3/8 INCH (M12*) SENSORS (All dimensions for reference only. mm/[in]) *Contact Honeywell for availability of metric mounting thread versions. General Specifications Parameter Characteristic Min. output 55 Vp-p voltage Coil resistance 275 Ohm to 330 Ohm Pole piece 2,36 ...

Page 7

... Maximum 40 kHz typ. operating frequency Vibration Mil-Std 202F Method 204D Termination 24 AWG, PVC-insulated leads Test Condition Specifications Parameter Characteristic Surface speed 25 m/s [1000 in/s] Gear 20 DP (module 1.27) Air gap 0,127 mm [0.005 in] Load 100 kOhm resistance Honeywell Sensing and Control 7 ...

Page 8

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or ...

Related keywords