LCA182 Clare, LCA182 Datasheet - Page 2

no-image

LCA182

Manufacturer Part Number
LCA182
Description
Solid State Relays SPST-NO 6PIN DIP
Manufacturer
Clare
Datasheet

Specifications of LCA182

Load Voltage Rating
350 V
Load Current Rating
120 mA
Mounting Style
SMD/SMT
Relay Type
Single Pole
Package / Case
DIP-6
Input Type
DC
Output Type
AC/DC
Input Voltage (max)
1.4V
Output Voltage (max)
350V
Input Current (max)
50mA
Output Current
120mA
Isolation Voltage
3750(RMS)V
Circuit Arrangement
1 Form A
Package Type
PDIP
Output Device
MOSFET
Pin Count
6
Mounting
Through Hole
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LCA182
Manufacturer:
IXYS/艾赛斯
Quantity:
20 000
Company:
Part Number:
LCA182
Quantity:
20
Part Number:
LCA182STR
Manufacturer:
Clare
Quantity:
1 883
LCA182
Electrical Characteristics
1
2
Absolute Maximum Ratings (@ 25˚C)
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Input Power Dissipation
Total Power Dissipation
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
Parameter
Output Characteristics @ 25°C
Load Current, Continuous
Peak Load Current
On-Resistance
Off-State Leakage Current
Switching Speeds
Output Capacitance
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
Input to Output Capacitance
It is recommended that the input control current be increased to 1mA in high temperature (>55ºC) operation.
Turn-On
Turn-Off
Peak (10ms)
1
2
AC/DC Configuration
DC Configuration
AC/DC Configuration
DC Configuration
Derate Linearly 1.33 mW/˚C
Derate Linearly 6.67 mW/˚C
1
2
1
-40 to +125
-40 to +85
Ratings
3750
350
150
800
50
5
1
I
F
Conditions
=1mA, V
50V; f=1MHz
Units
I
I
I
L
L
V
L
mW
V
t=10ms
I
mA
mW
=120mA
=200mA
=120mA
www.clare.com
V
V
°C
°C
F
L
V
A
rms
=350V
=1mA
R
P
=5V
-
-
-
L
=10V
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Symbol
C
I
R
t
I
LEAK
C
t
LPK
OFF
V
I
ON
OUT
I
I
I
ON
R
I/O
L
F
F
F
Min
0.05
0.9
-
-
-
-
-
-
-
-
-
Typ
1.2
23
25
7
3
-
-
-
-
-
-
-
-
Max
0.25
120
200
350
1.4
35
10
10
1
3
3
-
-
-
Units
mA
mA
mA
mA
µA
ms
µA
pF
pF
Ω
V
R02