ds_61B05_en_js: 090608D
SPECIFICATIONS
Contact
** Holding voltage should be 60% V of nominal voltage
Coil
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
*
*
TYPICAL APPLICATIONS
1. Home appliances
Types
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive
load)
Expected
life (min.
ope.)
Nominal operating power
1
2
Detection current: 10mA
Excluding contact bounce time
and desired reliability level, therefore it is recommended to check this with the
actual load.
Air conditioner, heater, etc.
Nominal switching
capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching
capacity
Mechanical
(at 180 cpm)
Electrical at 10 A
125 V AC,
6 A 277 V AC resistive
(standard)
10 A 277 V AC resistive
(High power)
10 A 250 V AC resistive
(Standard: at 20 cpm)
(High power: at 20 cpm,
105C 221F)**
.866
22
#1
16
.630
16
.630
mm
10 A 250 V AC
10 A 125 V AC
Standard type
6 A 277 V AC
(No contact
1 Form A,
1 Form C
5 10
inch
110
only)
250 V AC, 100 V DC
10 A (AC), 5 A (DC)
100 mA, 5 V DC
5
AgSnO
4
MINIATURE PC BOARD TYPE
2,500 VA
360 mW
100 m
FEATURES
• Miniature size with universal terminal
• High contact capacity: 10 A
• TV-5 type available (Standard type)
• VDE, TÜV also approved
• Sealed construction for automatic
• Class B and F coil insulation type
• EN60335-1 GWT compliant (Tested
• Surge voltage 6 kV type also
2. Automotive
10
footprint
1 Form A type TV-5
1 Form C type TV-5 (N.O. side only)
cleaning (Standard type)
also available.
by VDE) type available
available
Power-window, car antenna, door-lock,
etc.
2
7
endurance type
10 A 250 V AC
10 A 125 V AC
10 A 277 V AC
type
1 Form A
1.2 10
210
Long
POWER RELAY
5
5
Characteristics
*
*
*
*
*
Max. operating speed
Types
Initial insulation resistance
Initial
breakdown
voltage*
Operate time*
(at nominal voltage)
Release time (without diode)*
(at nominal voltage)
Temperature rise (at nominal voltage)
Shock resistance
Vibration resistance
Conditions for operation,
transport and storage*
(Not freezing and
condensing at low
temperature)
Unit weight
3
4
5
6
7
Half-wave pulse of sine wave: 11ms; detection time: 10s
Half-wave pulse of sine wave: 6ms
Detection time: 10s
Refer to “6. Usage, Storage and Transport Conditions“ in
ENVIRONMENT section in Relay Technical
When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1C
with 20C
maximum allowable voltage range.
1
68F
2
as a reference) and use a coil impressed voltage that is within the
Between open contacts
Between contacts and
coil
6
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances.
(The suffix “F” should be added to the
part number)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
3. Office machines
4. Vending machines
Functional*
Destructive*
Functional*
Destructive
Ambient
temp.*
Humidity
PPC, facsimile, etc.
JS RELAYS
2
7
3
5
4
Information.
Min. 100 M (at 500 V DC)
resistive, nominal voltage
Contact carrying current:
Standard
–40C to
–40F to
+185F
1,500 Vrms for 1 min.
10 to 55 Hz at double
10 to 55 Hz at double
+85C
amplitude of 1.6 mm
Approx.12 g
750 Vrms for 1 min.
10A, at 70C
type
amplitude of 2 mm
980 m/s
98 m/s
applied to coil.
5 to 85% R.H.
Max. 10 ms
Max. 10 ms
Max. 35C,
AMBIENT
20 cpm
2
2
endurance type
{10 G}
{100 G}
VDE
.423 oz
–40C to
–40F to
+105C
+221F
158F
Long
33.8F
JS
1