SLPP14-550P88 BANNER ENGINEERING, SLPP14-550P88 Datasheet - Page 6

no-image

SLPP14-550P88

Manufacturer Part Number
SLPP14-550P88
Description
SLPP14-550P88 EZ-SCREEN Low Profile Pair
Manufacturer
BANNER ENGINEERING
Type
Light Curtainr
Datasheet

Specifications of SLPP14-550P88

Resolution
14 Mm
Response (tr)
16.5 Ms
Beams
55
Range
0.1 To 7 M (4in. To 23ft.)
Height
550 Mm (21.7in.)
Connection
300 Mm Pigtail
Area, Active
550
Beam Spacing
14
Body Style
Rectangular
Primary Type
Photoelectric
Response Time
16.5 ms
Safety Outputs
2 PNP OSSD
Lead Free Status / Rohs Status
RoHS Compliant part
486
EZ-SCREEN
More information online at
EZ-SCREEN
Supply Voltage at the Device
Residual Ripple
Supply Current
Response Time
Remote Test Input
Wavelength of Emitter Elements
Recovery Time–Blocked to clear
(OSSDs turn ON; varies with total
number of sensing beams and
whether Sync beam is blocked)
EDM Input
Reset Input
Safety Outputs (OSSDs)
Auxiliary (Aux.) /Fault Output
Switching Capacity
Controls and Adjustments
Short Circuit Protection
Electrical Safety Class
(IEC 61140)
®
(TYPE 4 & TYPE 2)
®
Low-Profile 14 & 25 mm Resolution Specifications
bannerengineering.com
24V dc ±15% (use a SELV-rated supply according to EN IEC 60950)
(The external voltage supply must be capable of buffering brief mains interruptions of 20 milliseconds, as specified in
EN/IEC 60204-1.)
± 10% maximum
Emitter: 60 mA max., exclusive of fault load
Receiver: 150 mA max., exclusive of OSSD1 and OSSD2 loads (up to an additional 0.5A each) and Aux Output load (up to an
additional 0.25A)
8 to 43.5 milliseconds (see model number tables)
Cascade safety stop interface (CSSI): 40 milliseconds max. (contacts must be open for 60 milliseconds min.)
Test mode is activated either by applying a low signal (less than 3V dc) to emitter Test/Reset terminal for a
minimum of 50 milliseconds, or by opening a switch connected between Test/Reset and 24V dc for a minimum of 50 milliseconds.
Beam scanning stops to simulate a blocked condition. A high signal at Test/Reset deactivates Test Mode.
Infrared LEDs, 850 nm at peak emission
+24V dc signals from external device contacts can be monitored (one-channel, two-channel or no monitoring) via EDM1 and
EDM2 terminals in the receiver.
The Reset input must be high for 0.25 to 2 seconds and then low to reset the receiver.
Two redundant solid-state 24V dc, 0.5 A max. sourcing OSSD (Output Signal Switching Device) safety outputs. (Use optional
interface modules for ac or larger dc loads.)
Capable of the Banner “Safety Handshake”.
Current-sourcing (PNP) Solid-state output, 24V dc at 250 mA max. that follow safety outputs or lock out status (configurable)
Emitter:
Scan Code selection: 2-position switch (code 1 or 2). Factory default position is code 1.
Test/Reset: 2-position switch. Factory default position is Reset.
Invert Display: 2-position switch. Factory default position is OFF (Standard display).
Fault: 2-position switch. Factory default position is OFF.
Receiver:
Scan Code selection: 2-position switch (code 1 or 2). Factory default position is code 1.
Trip/Latch Output selection: Redundant switches. Factory default position is T (trip).
EDM/MPCE monitor selection: 2-position switch selects between 1- or 2-channel monitoring. Factory default position is
2-channel monitoring.
Reduced Resolution: Redundant switches. Factory default position is OFF.
Aux/Fault: 2-position switch. Factory default position is Aux.
Invert Display: 2-position switch. Factory default position is OFF.
All inputs and outputs are protected from short circuits to +24V dc or dc common.
III
14 mm Models
25 mm Models
High Signal: 10 to 30V dc
Low Signal: 0 to 3V dc
Input Current: 35 mA inrush, 10 mA max.
High Signal: 10 to 30V dc at 30 mA typical
Low Signal: 0 to 3V dc
High Signal: 10 to 30V dc at 30 mA typical
Low Signal: 0 to 3V dc
Closed Switch Time: 0.25 to 2 seconds
ON-State voltage: ≥ Vin-1.5V dc
OFF-State voltage: 1.2V dc max. (0-1.2V dc)
Max. load capacitance: 1.0 μF
Max. load inductance: 10 H
Leakage Current: 0.50 mA maximum
Cable Resistance: 10 Ω maximum
OSSD test pulse width: 100 to 300 microseconds
OSSD test pulse period: 10 to 22 milliseconds (varies with number of beams)
Switching Current: 0-0.5 A
Beam 1 (Sync Beam)
109 to 800 ms
81 to 495 ms
PICO-GUARD FIBER OPTIC (TYPE 4)
All Other Beams
33 to 220 ms
25 to 152 ms