DMPR1-E-400-1-30KW UA (UNITED AUTOMATION), DMPR1-E-400-1-30KW Datasheet

no-image

DMPR1-E-400-1-30KW

Manufacturer Part Number
DMPR1-E-400-1-30KW
Description
DUAL MODE POWER REG. 400V 30KW
Manufacturer
UA (UNITED AUTOMATION)
Datasheet

Specifications of DMPR1-E-400-1-30KW

Approval Bodies
CE
External Depth
205mm
External Length / Height
120mm
External Width
155mm
Fixing Centres
5mm
Fixing Centres Lxw
140x140
Input Voltage Max
230V
Mounting Type
4 Screw Fixing
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATIONS
Power/(current ratings):
Input voltage:
Frequency:
Control input signal:
Alarms relay circuit rating:
Status indicator:
Over temperature:
Zero Settings:
Span Setting:
Soft Start:
Current Limit:
Switch Options:
Cable terminations:
Terminal torque settings:
Fusing
Working temperature:
Dimensions:
Fixing centres:
Product Weight
Note: SAFETY WARNING –
FUNCTIONS
Alarm relay
The alarm circuit has voltage free relay contacts and are rated up to 2A @ 125V ac (RMS) load.
The internal supply to the relay is obtained from the transformer via two 20mm 1A fuses. These are connected to the Live and Neutral supply
and therefore the relay and LED can only energise when there is an over-temperature condition or sensor fault, as long as the supply is
present.
Over temperature protection
When the heat sink temperature rises above 40ºC (detected by the heat sink sensor) the cooling fan is switched on, if fitted. Should the heat
sink temperature reach 90ºC the power to the load will be disconnected and will not return until the temperature drops to 85ºC during this period
the alarm relay is enabled.
Temperature sensor loss
LED status changes to ON/OFF (fast pulsing) if the sensor fails.
Control Options
Phase Angle.
Burst Fire
Combination of Phase Angle and Burst Fire
INTRODUCTION
The complete enclosed single phase Dual Mode Power Regulator (DMPR)
thyristor assembly provides control of inductive/resistive loads of up to 30kW
at 415V. The user selectable control modes, via the internal switches are
either phase angle, burst firing or a combination of the two i.e. start up in
phase angle and then continue in burst firing. The controllers also come with
frequency tracking allowing the unit to be installed in many applications
where the supply is unstable. There are a number of signal control options to
meet most industrial requirements.
All are housed in a bespoke enclosure and have easy access to internal
signal & power terminals for simple installation. With Integral semiconductor
fuses and heatsink the controller offers a solution for many application
requiring single or dual mode control.
APPLICATIONS
Suitable for furnaces, ovens, dryers, air curtains, hot plates and many other
heating and ventilation applications
as transformers
SINGLE PHASE 12kW and 18kW RANGE
DUAL MODE POWER CONTROLLER
TWO PHASE 20kW and 30kW
12kW (52A): 18kW (78A) @ a typical supply of 240V RMS
20kW (48A): 30kW (72A) @ a typical supply of 400V RMS
230V RMS +/- 10%
415V RMS +/- 10% Phase to Phase
(115V AC Option Available on request)
4 to 400Hz active tracking
0 to 5Vdc up to a maximum of 24Vdc or Manual - 5K Potentiometer – 0-20mA/4-20mA
125V ac @ 2A
(Tracking control signal) LED indicator changes intensity
Trip in temperature @ 90ºC, +/- 1ºC (LED indicator ‘flashes’ continuous fast pulsing)
Fixed Level of 55°C brings on Fan (When Fitted)
Level of 85°C brings on alarm relay.
Level of 90°C shuts down power.
Sets the minimum output level, zero’s the output with signal of up to 2 volts
Sets the maximum output with input signals of up to 24 volts DC
0-30 seconds initiated at power up. Also initiated when enable is used
Built in and user resettable
To disable current limit and to enable current mode etc
Phase power (unit dependent)
Earth (unit dependent)
Remote supply Auxiliary alarm (relay)
Control signal -
4Nm (35mm² )
230V 80LET (12kW), 100LET (18kW) / 415V 80ET (20kW) 100ET (30kW) Semiconductor type, lug fuses
60°C (maximum operational)
205mm (L) x 155mm (W) x 120mm (H)
4 x 5mm ø holes on centres 140mm (W) x 140mm (L)
12kW (2.8kg): 18kW (3.5kg)
20kW (2.8kg): 30kW (3.5kg)
Isolate supply before removing cover; Metal parts, in particular the heatsink, may get very hot when the unit is
fully operational; DO NOT COVER enclosure ventilation slots.
.
Also suitable for inductive loads such
Features
DMR230-E-18kW
SHOWN
35mm² rising clamp terminal blocks
35mm² rising clamp terminal blocks
1.5mm² rising clamp terminal block
1.5mm² rising clamp terminal block
Phase Angle/Burst Fire Control or
Combination of both
Frequency Tracking 4-400Hz
Integral High Speed Fuses
Adjustable ramp control 1 to 30 seconds.
RoHS Compliant
SERIES
DMPR1
2002/95/EC
Directive
X10746

Related parts for DMPR1-E-400-1-30KW

DMPR1-E-400-1-30KW Summary of contents

Page 1

... Temperature sensor loss LED status changes to ON/OFF (fast pulsing) if the sensor fails. Control Options Phase Angle. Burst Fire Combination of Phase Angle and Burst Fire DMPR1 SERIES X10746 DMR230-E-18kW SHOWN Features Phase Angle/Burst Fire Control or Combination of both ...

Page 2

INSTALLATION Cooling requirements This robust stack assembly has an operational temperature of 60° C when naturally cooled and has a built in 90° C over temperature trip on the heatsink as a safety feature. The unit should be mounted vertically, ...