PAXCDC1C Red Lion Controls, PAXCDC1C Datasheet - Page 20
PAXCDC1C
Manufacturer Part Number
PAXCDC1C
Description
Extnd. RS485 Card W/Dual RJ11 Connector
Manufacturer
Red Lion Controls
Datasheet
1.PAXCDC2C.pdf
(32 pages)
Specifications of PAXCDC1C
Brand/series
PAXDR
Card Type
Option Communications
Communication
Serial RS485
Data Protocols
7/8 bits, 300 to 19,200 baud, no, even or odd parity
Pax Label Kit
189 Different Engineering Units, Labels Inserted Inside the Unit
Lead Free Status / Rohs Status
RoHS Compliant part
“
the chosen setpoint is programmed, the display will default to
the next setpoint to be programmed and continue the sequence for each setpoint.
Pressing PAR at
deactivated. Reverse (
deactivated.
6.6 MODULE 6 - S
” in the following parameters will reflect the chosen setpoint number.) After
Select a setpoint (alarm output) to open the remaining module menu. (The
Normal (
PAR
6-SPt
SPSEL
Setpoint
* BOUNDARY is the only Setpoint Action available for setpoints assigned to Totalizer C.
Select
PAR
PARAMETER
be installed into the PAX (see Ordering Information). Depending on the card installed, there will be two or four setpoint outputs
available. This section replaces the bulletin that comes with the setpoint plug-in card. Please discard the separate literature when using
the Plug-in card with the PAXDR. For maximum input frequency, unused Setpoints should be configured for
Operation
) turns the output “on” when activated and “off” when
Standby
Stb-n
Module 6 is the programming for the setpoint (alarms) output parameters. To have setpoint outputs, a setpoint Plug-in card needs to
The Setpoint Assignment and the Setpoint Action determine certain setpoint parameter availability. The chart below illustrates this.
SETPOINT OUTPUT LOGIC
) turns the output “off” when activated and “on” when
SETPOINT SELECT
OUt-n
will exit Module 6.
Output
Logic
Setpoint Output Logic
Setpoint Annunciator
Setpoint Power-Up State
Setpoint Value
Setpoint Tracking
Setpoint Boundary Type
Setpoint Standby Operation
Setpoint Hysteresis
Setpoint Off Delay
Setpoint On Delay
Setpoint Time Out
Totalizer Auto Reset
Reset With Display Reset
Reset When Spn+1 Activates
Reset When Spn+1 Deactivates
Hysteresis
Setpoint
HYS-n
Annunciator
DESCRIPTION
Setpoint
LIt-n
tOFF-n
Off Time
Delay
SETPOINT PARAMETER AVAILABILITY
ETPOINT
Assignment
Setpoint
ASN-n
On Time
tON-n
Delay
PARAMETER MENU
TIMED OUT
. Select
Setpoint
ACt-n
Action
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
(A
tOUt-n
Time-out
Value
LARM
20
RATE ASSIGNMENT
BOUNDARY
Power-up
the corresponding setpoint annunciator of an “on” alarm output. Reverse (
displays the corresponding setpoint annunciator of an “off” alarm output.
“on” alarm output.
SUP-n
State
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Select the display to which the setpoint is assigned.
Auto Reset
AUtO-n
Totalizer
) P
disables the display of the setpoint annunciator. Normal (
flashes the display and the corresponding setpoint annunciator of an
ARAMETERS
Setpoint
LATCH
Value
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
SP-n
when Display
Output Reset
Resets
SETPOINT ANNUNCIATORS
rSd-n
SETPOINT ASSIGNMENT
TIMED OUT
Tracking
trC-n
Setpoint
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Output Reset
when SPn+1
rSAS-n
Activates
TOTALIZER ASSIGNMENT
(
BOUNDARY *
action.
Boundary
tYP-n
Yes
Yes
Yes
Yes
Yes
Yes
Type
No
No
No
No
No
No
No
No
No
Output Reset
when SPn+1
Deactivates
rSAE-n
)
LATCH
Pro
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
) displays
)