CM400DX-12A Powerex Inc, CM400DX-12A Datasheet
CM400DX-12A
Specifications of CM400DX-12A
Related parts for CM400DX-12A
CM400DX-12A Summary of contents
Page 1
... Heat Sinking Applications: £ AC Motor Control £ Motion/Servo Control £ Photovoltaic/Fuel Cell Ordering Information: Example: Select the complete module number you desire from the table below -i.e. CM400DX-12A is a 600V (V ), CES 400 Ampere Dual IGBTMOD™ Power Module. Type Current Rating V CES ...
Page 2
... rating. j(max CHIP LOCATION (TOP VIEW) Chip Location (Top View) IGBT FWDi NTC Thermistor 21 Symbol CM400DX-12A T -40 to 150 j T -40 to 125 stg — 31 — 40 — 330 Grams — ±0 ~ +100 V 2500 ISO V ...
Page 3
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 CM400DX-12A Dual IGBTMOD™ NX-Series Module 400 Amperes/600 Volts Electrical and Mechanical Characteristics, T Inverter Sector Characteristics Collector Cutoff Current Gate-Emitter Threshold Voltage Gate Leakage Current Collector-Emitter Saturation Voltage Input Capacitance Output Capacitance ...
Page 4
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 CM400DX-12A Dual IGBTMOD™ NX-Series Module 400 Amperes/600 Volts OUTPUT CHARACTERISTICS (INVERTER PART - TYPICAL) 800 T = 25° 20V 12 13 600 11 400 200 COLLECTOR-EMITTER VOLTAGE (VOLTS) CE FREE-WHEEL DIODE FORWARD CHARACTERISTICS (INVERTER PART - TYPICAL) ...
Page 5
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 CM400DX-12A Dual IGBTMOD™ NX-Series Module 400 Amperes/600 Volts SWITCHING LOSS VS. COLLECTOR CURRENT (INVERTER PART - TYPICAL 300V ±15V 3.6Ω 125°C j Inductive Load off COLLECTOR CURRENT (AMPERES) C REVERSE RECOVERY SWITCHING LOSS VS. ...