D4C-3320 Omron, D4C-3320 Datasheet
D4C-3320
Specifications of D4C-3320
Related parts for D4C-3320
D4C-3320 Summary of contents
Page 1
... Wiring Specifications Internal switch Connector COM CSM_D4C_DS_E_2_1 Weather-resistant Models D4C-@@@-P (1)(2)(3) (4) (1) Rated Current 250 VAC VDC 125 VAC (with LED indicator VDC (with LED indicator 125 VAC, 0 VDC (2) Cable Specifications 2: VCTF oil-resistant cable ( VCTF oil-resistant cable (5 m) (3) Actuator ...
Page 2
... Note: 1. Models are available separately with resistance to viscous oils (oil drain holes are also available), but only with Plunger Models. Add “-M” to the model number (example: D4C-1202 would be D4C-1202-M). 2. Switches with variable roller levers are also available. Ask your nearest OMRON representative for details. ...
Page 3
... Ordinary vinyl cabtire cables.; approved by EN and IEC. 0 125 VAC VCTF cable *2 Model D4C-2401 D4C-3201 D4C-2501 D4C-3301 D4C-2402 D4C-3202 D4C-2502 D4C-3302 D4C-2403 D4C-3203 D4C-2503 D4C-3303 D4C-2420 D4C-3220 D4C-2520 D4C-3320 D4C-2424 D4C-3224 D4C-2524 D4C-3324 D4C-2431 D4C-3231 D4C-2531 D4C-3331 D4C-2432 D4C-3232 D4C-2532 D4C-3332 D4C-2433 D4C-3233 D4C-2533 D4C-3333 D4C-2450 D4C-3250 ...
Page 4
... D4C-6201 D4C-6301 D4C-6202 D4C-6302 D4C-6203 D4C-6303 D4C-6220 D4C-6320 D4C-6224 D4C-6324 D4C-6231 D4C-6331 D4C-6232 D4C-6332 D4C-6233 D4C-6333 D4C-6250 D4C-6350 125 VAC With operation indicator Without operation indicator D4C-2001-AK1EJ@ D4C-2002-AK1EJ@ D4C-2031-AK1EJ@ D4C-2032-AK1EJ@ D4C-2024-AK1EJ@ D4C VDC With operation indicator D4C-1001-DK1EJ@ D4C-3001-DK1EJ@ D4C-1002-DK1EJ@ D4C-3002-DK1EJ@ D4C-1031-DK1EJ@ ...
Page 5
... Center roller lever Note: 1. The model numbers for heads are of the form D4C-00@@, with the numbers in the squares indicating the type of actuator. 2. Actuators for plunger models, plastic rod models, and center roller lever models cannot be ordered individually. They must be ordered together with the head. ...
Page 6
... D4C-1@@@ DC-12 2 A/30 V D4C-2@@@ AC-15 2 A/125 V D4C-3@@@ DC-12 2 A/30 V AC-14 0.1 A/125 V D4C-4@@@ DC-12 0.1 A/30 V D4C-5@@@ AC-14 0.1 A/125 V D4C-6@@@ DC-12 0.1 A/30 V UL/CSA B300 (D4C-16@@, -17@@) B150 (D4C-26@@, -27@@) B300 Current (A) Rated voltage Carry current Make Break 120 VAC 240 VAC 15 1 ...
Page 7
... Head-mounting Screw Diaphragm The diaphragm is made of silicone rubber and is resistant to temperature changes and adverse weather conditions. Cable Vinyl cabtire cable and is resistant to adverse weather conditions. D4C-4 @@@ , -5 @@@ , -6 @@@ 1,000 700 Operating temperature: 5°C to 35°C 500 Operating humidity: 40% to 70% ...
Page 8
... Use only a straight connector. Note: “Lit when not Actuated” means that when the actuator is in the free position, the indicator is lit, and when the actuator is turned or pushed and the contact comes into contact with the NO side, the indicator turns OFF. D4C , -DK1EJ ) @ @ NC Pin No ...
Page 9
... Spot facing VCTF cable, * 10.2 dia. Depth 0. conductor 2 1.4 Finishing 34 O.D.: 7.6 * S-FLEX VCTF Cables are used for weather-resistant models. D4C-@@20 D4C-@@24 D4C-@@20-P D4C-@@24-P 5.69 N 5.69 N 1.47 N 1.47 N 25° 10°±3° 40° 50° 3° 3° --- ...
Page 10
... Rubber cap 16 +0.2 Two, 5.1 dia. 0 holes Spot facing 10.2 dia. Depth: 6 4.0 7 1.4 1.5 D4C-@@32 D4C-@@33 17.65 N 17.65 N 4.41 N 4.41 N 1 0.2 mm 0.2 mm 34.3±1 mm 34.3±1 mm (5) mm (5) mm D4C 12 dia. x 4.4 stainless steel roller 40 max. Rubber cap PT 25 ± ...
Page 11
... Models with LED Indicator D4C-@@60 The dimensions of the LED 6.67 N indicator for models equipped with 1.47 N one are shown below. 10°±3° 50° 3° --- --- Roller Plunger D4C-@002-@K1EJ@ D4C-@002-M1J@ dia. PT Correct setting position 16 2 max. 51.5 max. 1.5 1.4 6 dia ...
Page 12
... Two, 5.1 dia holes Spot facing 10.2 dia. Depth XS2H-D421 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Sealed Roller Plunger D4C-@032-@K1EJ@ D4C-@032-M1J max. 1.5 1.4 6 dia. D4C-@032 -@K1EJ@ 17.65 N 4. 0.2 mm 34.3± max. 44 ± ...
Page 13
... Movement Differential MD max. 3° * Operation characteristics for the D4C-@@27-P and D4C- @@29-P are for a lever length of 38 mm. Safety Precautions Refer to Safety Precautions for All Limit Switches. Precautions for Correct Use Operating Environment • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals ...
Page 14
... Do not expose the Switch to water exceeding 70°C or use it in steam. • When the D4C is used in a circuit of a device to be exported to Europe, classified as Overvoltage Class III as specified in IEC664, provide a contact protection circuit. • Tighten each screw to a torque according to the following table. ...
Page 15
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...