1490413-2 TE Connectivity, 1490413-2 Datasheet
1490413-2
Specifications of 1490413-2
Related parts for 1490413-2
1490413-2 Summary of contents
Page 1
... GAlso used for STRATO- - THERM* Heat Resistant Uninsulated Terminals zRTT=Ring Tongue Terminals [BS=Butt Splice YPS=Parallel Splice DDies for Heavy Duty Terminals +90 Bend Terminals 1 ...
Page 2
Tools Using Crimping Dies for SOLISTRAND Terminals and Splices (Refer to Figure 1) Hydraulic Head 1490747 Hydraulic Head 1901821 All dimensions on this document are in metric NOTE units [with U. S. customary units in brackets]. ...
Page 3
Indenter 4. WIRE STRIPPING AND CRIMPING PROCEDURES 4.1. Wire Stripping Strip wire to the dimensions listed in Figure 4. Do NOT nick or cut the wire strands. 4.2. Crimping Procedure To avoid personal injury, be sure to exercise DANGER caution ...
Page 4
Terminal B NOMINAL WIRE NOMINAL WIRE 2 mm SIZE 2 mm AWG CMA RANGE 6.637--10.539 7--8 8 [13,100- - 20.800] 10.539--16.771 13--15 6 [20,800--33,100] 16.771--26.653 21 4 [33,100--52,600] 26.653--42.411 34--35 2 [52,600- - 83,700] 42.411--60.551 59--60 1/0 [83,700- - 119,500] ...
Page 5
Terminal 1 4 Wire Range 2 Stamped Under Tongue Sight Standard or Hole Type Wire Range Strap 2 Stamped Here Type Crimps centered. Crimps may be off center BUT NOT OFF 1 END OF WIRE ...
Page 6
Flattened Pitted Figure 7 B. Gaging the Crimping Chamber (Figures 8 and 9) The inspection requires the use of a plug gage conforming to the dimensions in Figure 9. Tyco Electronics does not manufacture or market these gages. Proceed as ...
Page 7
... Rev E SUGGESTED PLUG GAGE DESIGN “ ...