B41044A3478M EPCOS Inc, B41044A3478M Datasheet - Page 35

no-image

B41044A3478M

Manufacturer Part Number
B41044A3478M
Description
Manufacturer
EPCOS Inc
Type
Electrolyticr
Datasheet

Specifications of B41044A3478M

Tolerance (+ Or -)
20%
Voltage
10VDC
Mounting Style
Through Hole
Construction
Radial
Dcl
4uA
Lifetime
5000
Product Diameter (mm)
16mm
Product Height (mm)
25mm
Product Depth (mm)
Not Requiredmm
Product Length (mm)
Not Requiredmm
Lead Spacing (nom)
7.5mm
Lead Diameter (nom)
0.8mm
Operating Temp Range
-40C to 105C
Capacitance
4700uF
Ripple Current
2.1A
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B41044A3478M000
Manufacturer:
EPCOS
Quantity:
30 000
Part Number:
B41044A3478M001
Manufacturer:
EPCOS
Quantity:
30 000
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling aluminum electrolytic capacitors:
Please read Cautions and warnings and
Important notes at the end of this document.
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Low impedance & high ripple current
Page 35 of 40
B41044, B43044
105 C

Related parts for B41044A3478M