AD7887AR-REEL7 Analog Devices Inc, AD7887AR-REEL7 Datasheet - Page 16

no-image

AD7887AR-REEL7

Manufacturer Part Number
AD7887AR-REEL7
Description
IC,Data Acquisition System,2-CHANNEL,12-BIT,SOP,8PIN,PLASTIC
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7887AR-REEL7

Rohs Status
RoHS non-compliant
Design Resources
Software Calibrated, 1 MHz to 8 GHz, 70 dB RF Power Measurement System Using AD8318 (CN0150)
Number Of Bits
12
Sampling Rate (per Second)
125k
Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Converters
1
Power Dissipation (max)
3.5mW
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Lead Free Status / RoHS Status
AD7887
DOUT
DOUT
SCLK
SCLK
DIN
DIN
CS
CS
DOUT
SCLK
DIN
THE FIRST EIGHT CLOCKS. PM1 = 1 AND PM0 = 0
CS
CONTROL REGISTER DATA IS LOADED ON
CONTROL REGISTER DATA IS LOADED ON THE
FIRST EIGHT CLOCKS. PM1 = 1 AND PM0 = 0
1
1
FOUR LEADING ZEROS + CONVERSION RESULT
FOUR LEADING ZEROS + CONVERSION RESULT
SHUTDOWN AT THE END
1
THE FIRST EIGHT CLOCKS. PM1 = 1 AND PM0 = 1
DATA IN
DATA IN
+ CONVERSION RESULT
OF CONVERSION AS
PM1 = 1 AND PM0 = 0
FOUR LEADING ZEROS
THE PART ENTERS
DATA IN
CONTROL REGISTER DATA IS LOADED ON
CONVERSION AS PM1 = 1 AND PM0 = 0
8
SHUTDOWN AT THE END OF
THE PART ENTERS
Figure 19. Mode 3 Operation (Microcontroller for High Speed SCLKs)
16
Figure 18. Mode 3 Operation (Microcontroller for Slow SCLKs)
STANDBY AT THE END OF
THE PART BEGINS TO POWER
PM1 = 1 AND PM0 = 1
THE PART ENTERS
CONVERSION AS
UP FROM SHUTDOWN
Figure 20. Mode 4 Operation
16
1
16
Rev. D | Page 16 of 24
DATA IN
PM1 = 0 AND PM0 = 1 TO PLACE
+ CONVERSION RESULT
THE PART IN NORMAL MODE
FOUR LEADING ZEROS
SHUTDOWN ON SCLK FALLING EDGE AS
8
THE PART POWERS UP FROM
THE PART REMAINS POWERED UP
PM1 = 1 AND PM0 = 0
AS PM1 = 0 AND PM0 = 1
FALLING EDGE AS PM1 = 1
FROM STANDBY ON SCLK
THE PART POWERS UP
PM1 = 1 AND PM0 = 0 TO KEEP THE
16
t
1
10
1
AND PM0 = 1
= 5µs
PART IN THIS MODE
FOUR LEADING ZEROS + CONVERSION RESULT
2
FOUR LEADING ZEROS + CONVERSION RESULT
DATA IN
DATA IN
PM1 = 1 AND PM0 = 1 TO KEEP
1
DATA IN
+ CONVERSION RESULT
PM1 = 1 AND PM0 = 0 TO PLACE
THE PART IN THIS MODE
FOUR LEADING ZEROS
THE PART BACK IN MODE 3
SHUTDOWN AT THE END OF
CONVERSION AS PM1 = 1
THE PART ENTERS
8
AND PM0 = 0
16
16
16

Related parts for AD7887AR-REEL7