D3002 Tyco Electronics, D3002 Datasheet - Page 8

D3002=FP RELAY 140 MW 12 V

D3002

Manufacturer Part Number
D3002
Description
D3002=FP RELAY 140 MW 12 V
Manufacturer
Tyco Electronics
Series
FP2, AXICOMr
Datasheets

Specifications of D3002

Rohs Compliant
YES
Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Standard
Coil Current
11.7mA
Coil Voltage
12VDC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
2 Form C (DPDT)
Power Consumption
140 mW
Maximum Switching Current
2 A
Contact Carry Current
2 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
1462033-5
D3002
PB1067

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D3002
Manufacturer:
CY
Quantity:
158
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Insulation
High Frequency Data
Capacitance
RF Characteristics
General Data
Insulation resistance at 500 Vdc
Dielectric test voltage (1 min)
Surge voltage resistance
Operate time at U
Reset time (latching) at U
Release time without diode in parallel (non-latching), typ. / max.
Release time with diode in parallel (non-latching), typ. / max.
Bounce time at closing contact, typ. / max.
Maximum switching rate without load
Ambient temperature
Thermal resistance
Maximum permissible coil temperature
Vibration resistance (function)
Shock resistance, half sinus, 11 ms
Degree of protection / Environmental protection
Needle flame test
Mounting position
Processing information
Weight (mass)
Terminal surface
Resistance to soldering heat
between coil and contacts
between adjacent contact sets
between open contacts
Isolation at 100 MHz / 900 MHz
Insertion loss at 100 MHz / 900 MHz
V.S.W.R. at 100 MHz / 900 MHz
between coil and contacts
between adjacent contact sets
between open contacts
according IEC (10 / 700 μs)
between coil and contacts
between adjacent contact sets
between open contacts
according to FCC 68 (10 / 160 μs)
between coil and contacts
between adjacent contact sets
between open contacts
nom
typ. / max.
nom
, typ. / max.
AXICOM
Telecom-, Signal and RF Relays
FP2 Relay
All data refers to 23 °C unless otherwise specified.
application time 20 s, no burning or glowing
Ultrasonic cleaning is not recommended
immersion cleanable, IP 67 / RT III
- 0.03 dB / - 0.25 dB
- 40.2 dB / - 22.3 dB
1500 G (damage)
-55 °C ... +85 °C
50 operations/s
50 G (function)
265 °C / 10 s
10 to 500 Hz
3 ms / 4 ms
3 ms / 4 ms
1 ms / 3 ms
3 ms / 4 ms
1 ms / 5 ms
1000 Vrms
1000 Vrms
1.01 / 1.07
< 150 K/W
max. 4 pF
max. 1 pF
max. 1 pF
750 Vrms
SnCu 0.7
max. 2 g
> 10
1500 V
1500 V
1500 V
1500 V
1500 V
1500 V
125 °C
20 G
any
9
Ω
108-98005 Rev. E
8 of 11