J73KN-B-10 Omron, J73KN-B-10 Datasheet

no-image

J73KN-B-10

Manufacturer Part Number
J73KN-B-10
Description
1 NO Aux Contact
Manufacturer
Omron
Datasheet

Specifications of J73KN-B-10

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
J73KNB10
Main contactor
• AC & DC operated
• Integrated auxiliary contacts
• Screw fixing and snap fitting (35 mm DIN rail) up to 37 kW
• Range from 4 to 110 kW (AC 3, 380/415V)
• Finger proof (BGV A2)
• System contactors for Fuseless Load Feeders with integrated
Accessories
• front mounted single pole additional auxiliary contacts
• Side mounted additional auxiliary contacts (1 NO/1 NC)
• Mechanical interlock
• Suppressors (RC and varistor)
• Pneumatic timer modules
• Link modules MPCB - Motor contactor
Approved Standards
Standard
UL
IEC 947-4-1
VDE 0660
EN 60947-4-1
link module
(1 NO or 1 NC)
Motor Contactor
J7KN
Guide No (US,C)
NLDX, NLDX7
see page 95
Motor Contactor
J7KN
25

Related parts for J73KN-B-10

J73KN-B-10 Summary of contents

Page 1

Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting (35 mm DIN rail • Range from 4 to 110 kW (AC 3, 380/415V) • Finger ...

Page 2

... AC180-210V 50Hz, AC200-240V 60Hz 230: AC220-240V 50Hz, AC240V 60Hz 400: AC380-415V 50Hz, AC415-440V 60Hz 500: AC500-550V 50Hz, AC550-600V 60Hz 5) Attached link module Aux. Contact Modules for Motor Contactors J73KN-#-##-# Auxiliary Contact Modules 2) B: for motor contactor (4-37kW) C: for motor contactor (11-37kW) ...

Page 3

... LG-11224: for Motor Contactors (75-90 kW) Additional Terminal for Single Pole LG-10404: for Motor Contactors (75-90 kW) Terminal Cover for 3 terminals Marking Systems for contactors J7KNA - J7KN 74 and aux. contact blocks J73KN-B P487-1: Marking plate, 2-section without marking, divisible P245-1: Marking plate, 4-section without marking, divisible 9 ...

Page 4

... Inrush Hold Operation range of coils 0,85 - 1,1 Mounting 35mm DIN-rail or base Additional aux. contact blocks Front mounting contact configuration maximal 4 J73KN-B.. Additional aux. contact blocks Side mounting - contact configuration Overload Relay (thermal) Single phase protection Temperature compensation Trip and alarm contacts ...

Page 5

Ratings AC3 400V Motor 85A 380-400V 45kW 660-690V 55kW AC1 690V at 40°C 150A Type J7KN- 85-22 Auxiliary contacts 2NO+2NC 2NO+2NC - Type - Auxiliary contacts - Cable cross-section 2 Solid Flexible ...

Page 6

... Current AC1 Built-in 660V 690V 690V 150 170 230 - - max J73KN- 90 250 - - D22F J73KN- D11F and 2 x J73KN- D11S 132 350 2 1 J73KN-E- 22 Type Pack *1 Coil Voltage 24 24V 50/60Hz 110 110V 50Hz 230 220-240V 50Hz pcs. J7KN-10-10### 1 J7KN-10-01### 1 J7KN-14-10### 1 J7KN-14-01### 1 J7KN-18-10### ...

Page 7

... Built- J7KN-85-21### J7KN-110-21### max. 3 J7KN-151-### 1 x J73KN- J7KN-176-### D22 J73KN- D11 and 2 x J73KN- D11S 2 1 J7KN-200-21### *1 Only 3 additional Aux. Contacts are possible! (See also the wiring diagrammms coil circuit DC operated page 35 and DC in one coil Coil voltage Pack Weight Accept Overload ...

Page 8

... Current AC1 Built-in Additional see 690V below Type max. 4 J73KN 230 - - max. 3 J73KN-D-11F 250 - - J73KN-D-22F J73KN-D-11S Rated Aux. Contacts see page 33 Current AC1 Built-in Additional see 690V below Type max. 4 J73KN (see page 72) Type Pack *1 Coil Voltage 24 24V 50/60Hz ...

Page 9

... Mounting + Type + J7KN10 - J7KN40 horizontal + J7KN24 - J7KN74 horizontal + J7KN85 - J7KN110 horizontal J7KN151 - J7KN176 horizontal Type Pack EM LB pcs J73KN-B- J73KN-B- J73KN-B-10U J73KN-B-01U J73KN-B-10A J73KN-B-01A 10 Contacts Type Pack NO NC pcs J73KN-D-11F J73KN-D-22F J73KN-D-11S 1 Contacts Type Pack NO NC pcs J73KN-C-11S J73KN-E-22 1 Type Pack pcs ...

Page 10

... Additional Terminals Single Pole For Contactors J7KN50 - KN74 J7KN151 - KN176 Terminal Covers for terminal protection according DIN 57106, BVG-A2 For Contactors J7KN151 - KN176 Marking Systems for contactors J7KNA to J7KN74 and aux. contact blocks J73KN-B Description Marking Plate Marking Plate J7KN 34 Motor Contactor ...

Page 11

Insulated wiring systems for motor contactors Description For reversing or parallel contactors ( 2 parts ) For star-delta combination (3 parts) ■ Wiring Diagrams Coil Circuit AC operated DC operated with double winding coil* J7KN-10... J7KN-10... J7KN-110... J7KN-22...D ...

Page 12

Specifications ■ Coil Voltages Type-suffix for contactor types J7KN-10... to J7KN-74... Suffix Voltage Marking Rated Control Voltage U to contactor at the coil range for type e.g. 50Hz J7KN-10-10-24 for 50Hz for 60Hz min ...

Page 13

Engineering data and characteristics Approximate Values for three-phase Motors Motor Full Load Currents Approximate values of motor F.L.C. and minimum „slow blow“ respectively „gL“ short-circuit fuse Motor rating 220-230V Motor Range according to BS for 415V Value of fusing ...

Page 14

Approximate values of motor F.L.C. according to CSA and UL Motor Motor F.L.C. at 110-120V rating 1-phase 2-phase 3-phase ½ 9.8 4.0 4.4 ¾ 13.8 4.8 6.4 1 16.0 6.4 8.4 1½ 20.0 9.0 12.0 2 ...

Page 15

Contactors Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Main Contacts Type Rated insulation voltage 690 i Making capacity 690V AC A eff e Breaking capacity I 400V AC A eff ...

Page 16

Main Contacts Type Utilization category AC4 Switching of squirrel cage motors, inching Rated operational power 220-230V kW of three-phase motors 240V kW 50-60Hz 380-400V kW 415V kW 440V kW 500V kW 660-690V kW 1000V kW Utilization category AC 5a Switching ...

Page 17

Main Contacts Type Utilization category DC3 and DC5 Switching of shunt motors and series motors Time constant L/R 15ms Rated operational current I 1 pole24V A e 60V A 110V A 220V A 3 poles in series 24V A 60V ...

Page 18

Main Contacts Type J7KN-85 *1 Rated insulation voltage 750 i Making capacity 690V AC A eff e Breaking capacity I 400V AC A eff J7KN-10 to J7KN-22 cosϕ = 0,65 500V AC A ...

Page 19

Main Contacts Type J7KN-85 Rated operational power 220-230V kW of three-phase motors 240V kW 50-60Hz 380-400V kW 415V kW 440V kW 500V kW 660-690V kW 1000V kW Utilization category AC 5a Switching of gas discharge lamps Rated operational current I ...

Page 20

Main Contacts Type J7KN-85 Utilization category DC3 and DC5 Switching of shunt motors and series motors Time constant L/R 15ms Rated operational current I 1 pole24V A e 60V A 110V A 220V A 3 poles in series 24V A ...

Page 21

Contactors Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Auxiliary Contacts Type J7KN-10 *1 Rated insulation voltage Thermal rated current I to 690V th Ambient temperature 40°C A 60°C A Utilization category AC15 Rated operational current ...

Page 22

Auxiliary Contacts Type J7KN-85 *1 Rated insulation voltage Thermal rated current I to 690V th Ambient temperature 40°C A 60°C A Utilization category AC15 Rated operational current I 220-240V A e 380-415V A 440V A 500V A ...

Page 23

Contactors for North America Data according to UL508 Main Contacts (cULus) Type J7KN-10 Rated operational current A "General Use" Rated operational power 110-120V hp of three-phase motors 200V hp at 60Hz (3ph) 220-240V hp 277V hp 380-415V hp 440-480V hp ...

Page 24

Contactors Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Contact Life For selection of the suitable contactor-type according to supply volt- age, power rating and application (utilization category AC1, AC3 or AC4) use contact life characteristic diagram. For the ...

Page 25

Contactors Utilization Categories For easier choice of devices and in order to make the comparison of different products simplier are utilization categories for contactors and motor-starters according to IEC 947-4-1 and VDE 0660 Part 102 ,for Type of Cate- Typical ...

Page 26

... Data according to CSA, UL and CUL Auxiliary Contacts Type J73KN-B Rated operational current A „General Use“ Rated operational voltage max 600 Auxiliary Contacts Contactors and Accessories Wiring diagrams Auxiliary contact blocks J73KN-B-10 J73KN-B-01 J73KN-D-11 J73KN-D-11S *1 Correct terminal marking is given by mounting J7KN 50 Motor Contactor J73KN-C J73KN-D J74KN-B-TP... ...

Page 27

Dimensions AC operated J7KN-10/14/18/22(-4)... 45 35-36 Ø5 M3.5 J7KN-24/32/40... Ø4,5 M5 J7KN-50/62/74... Ø5.5 M6 Auxiliary contacts are optional DC operated J7KN-10/14/18/22...D 82.5 78.5 6.5 50 J7KNG-10/14/18/22(-4)...D J7KN-24/32/40...D 104.5 100.5 6.5 63 ...

Page 28

AC and DC operated J7KN-85... J7KN-110... J7KN-151... J7KN-176... Auxiliary contacts are optional Pneumatic timer J74KN-B-TP... J7KN 52 Motor Contactor J7KN-200... ...

Page 29

Auxiliary contact blocks J74KN-A-VG J74KN-B-VG J74KN J74KN-D 150 J74KN-B-RC Motor Contactor J7KN 53 ...

Page 30

... J7KN-18-10...D J7KN-18-01...D J7KN-22-10...D J7KN-22-01...D AC and DC operated J7KN-200-21 J7KN-151 J7KN-176 Do not use/install these products before having read the applicable precautions as listed in Cat. No. J09-EN-01 available from www.europe.omron.com or on request from OMRON local sales office. J7KN 54 Motor Contactor J7KN-24 J7KN-50 J7KN-32 J7KN-62 J7KN-40 J7KN-74 J7KN-24 ...

Page 31

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 32

... OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • ...