NS5-TQ11B-V2 Omron, NS5-TQ11B-V2 Datasheet - Page 164
NS5-TQ11B-V2
Manufacturer Part Number
NS5-TQ11B-V2
Description
5 TFT Clr,ETN+Serial+USB,Bk 60
Manufacturer
Omron
Datasheet
1.NS12-TS01B-V2.pdf
(334 pages)
Specifications of NS5-TQ11B-V2
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 164 of 334
- Download datasheet (7Mb)
5-2 Connecting to the Host Using Controller Link
5-20
Setting Data Link Tables
To perform data links, data link tables are required. Set data link tables by following the steps
below.
1. Set data link tables using the CX-Net (Network Configurations Tool).
PT Model
Node
First data link status
word
Area 1 Data link
Area 2 Data link
Data link tables are created to define data links. These tables must be set for each node
participating in data links. Refer to the manual for CX-Programmer for the method of set-
ting.
The following table shows the items and setting range for data link tables in the Control-
ler Link Support Board mounted on the PT.
Setting item
start word
(See note.)
Number of
words
Offset
start word
(See note.)
Number of
words
Offset
Set the address of the refresh nodes.
If a number is set, it will be invalid because the first word to store data link
status is fixed.
Set ”-“.
$B0 to $B32767
$W0 to $W24575
Use CIO for $B and D for $W in the CX-Net.
The same area cannot be set for both area 1 and area 2. Set different areas.
• Remote nodes:
• Local nodes:
The total number of words in area 1 and area 2 in each node must not exceed
1,000.
The number of words in both area 1 and area 2 in each node must not be set
to 0.
•
• Local nodes:
$B0 to $B32767
$W0 to $W24575
Use CIO for $B and D for $W in the CX-Net.
The same area cannot be set for both area 1 and area 2. Set different areas.
• Remote nodes: 0 to the number of source words
• Local nodes:
The total number of words in area 1 and area 2 in each node must not exceed
1,000.
The number of words in both area 1 and area 2 in each node must not be set
to 0.
• Remote nodes: 0 to one less than number of source words
• Local nodes:
Set as a "NSB."
1 to 32
Remote nodes: 0 to one less than number of source words
0 to the number of source words
Set the number of words to be received
0 to 1000
Set the number of words to be transmitted
Set offset for data to be received
Cannot be set.
This setting is not required if an offset is not used.
Set the number of words to be received
0 to 1000
Set the number of words to be transmitted
Set offset for data to be received
Cannot be set.
This setting is not required if an offset is not used.
Setting range
Related parts for NS5-TQ11B-V2
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: