3.4 Consecutive Read
The host can request information from consecutive addresses by adding an additional ? for the human
readable decimal format or an additional $ for the 2s-complement hex format.
An example of requests for the contents in decimal of ten consecutive addresses starting with 0x12 is:
>)12??????????<CR>
An example of requests for the contents in hex of ten consecutive addresses starting with 0x12 would be:
>)12$$$$$$$$$$<CR>
Note: The number of characters per line is limited to no more than 60.
3.5 Block Reads
The block read command can also be used to read consecutive registers: )saddr:eaddr? For decimal
format or )saddr:eaddr$ for hex format where saddr is the start address and eaddr is the final address.
The following block read command requests the returned information to be displayed in human readable
decimal format:
>)20:3D?<CR>
3.6 Concatenated Reads
Multiple commands can also be added on a single line. Requesting information in human readable
decimal from two locations and the block command from above are given below:
>)12?)15?)20:3D?<CR>
Note: The number of characters per line is limited to no more than 60.
3.7 Relay Control
The 78M6612 Split Phase Evaluation Board incorporates relays to cutoff current to each phase. The two
relays are controlled by a single 78M6612 DIO output. The following CLI commands are used to control
the relay operation:
18
CLI Command
F0=1 or TC1
F0=0 or TC0
Table 6: CLI Relay Commands
Contacts Closed – Load On
Contacts Open – Load Off
Relay Operation
UM_6612_044