EMC2303-1-KP-TR Standard Microsystems (SMSC), EMC2303-1-KP-TR Datasheet - Page 13

no-image

EMC2303-1-KP-TR

Manufacturer Part Number
EMC2303-1-KP-TR
Description
Manufacturer
Standard Microsystems (SMSC)
Datasheet

Specifications of EMC2303-1-KP-TR

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
12
Lead Free Status / RoHS Status
Compliant
Multiple RPM-Based PWM Fan Controller for Three Fans
Datasheet
SMSC EMC2303
3.1.3
3.1.4
3.1.5
3.1.6
3.1.7
PULL-UP RESISTOR
4.7k Ohm ±5%
6.8k Ohm ±5%
10k Ohm ±5%
15k Ohm ±5%
22k Ohm ±5%
33k Ohm ±5%
SMBus Data Bytes
All SMBus Data bytes are sent most significant bit first and composed of 8-bits of information.
SMBus ACK and NACK Bits
The SMBus client will acknowledge all data bytes that it receives (as well as the client address if it
matches and the ARA address if the ALERT# pin is asserted). This is done by the client device pulling
the SMBus Data line low after the 8th bit of each byte that is transmitted.
The Host will NACK (not acknowledge) the data received from the client by holding the SMBus data
line high after the 8th data bit has been sent.
SMBus Stop Bit
The SMBus Stop bit is defined as a transition of the SMBus Data line from a logic ‘0’ state to a logic
‘1’ state while the SMBus clock line is in a logic ‘1’ state. When the EMC2303 detects an SMBus Stop
bit has been communicating with the SMBus protocol, it will reset its client interface and prepare to
receive further communications.
SMBus Time-out
The EMC2303 includes an SMBus timeout feature. Following a 30ms period of inactivity on the
SMBus, the device will time-out and reset the SMBus interface.
The SMBus timeout feature is disabled by default and can be enabled via clearing the DIS_TO bit in
the Configuration register (20h).
SMBus and I
The major difference between SMBus and I
information refer to the SMBus 2.0 specification.
1. Minimum frequency for SMBus communications is 10kHz (I
2. The slave protocol will reset if the clock is held low for longer than 30ms (I
3. The slave protocol will reset if both the clock and data lines are held high for longer than 150us.
4. I
2
C devices do not support the Alert Response Address functionality (which is optional for SMBus).
2
C Compliance
Table 3.1 ADDR_SEL Pin Decode
0101_110(r/w)
0101_111(r/w)
0101_100(r/w)
0101_101(r/w)
1001_100(r/w)
1001_101(r/w)
SMBUS ADDRESS
DATASHEET
13
2
C devices is highlighted here. For complete compliance
2
C has no minimum frequency).
None - CLK pin used as clock input
or output
CLK pin used to determine default
fan drive - see
CLK pin cannot be used as a clock
input or output
ADDITIONAL FUNCTIONS
2
C has no timeout).
Section
Revision 1.2 (03-22-10)
4.5.1. The