... All inspections shall be perform ed using the applicable inspection plan and product drawing. 1.3. Successful qualification testing on the subject product line was com pleted on 20Apr09. The Qualification Test Report num ber for this testing is 501-703. This docum entation is on file at and available from Engineering Practices and Standards (EPS). ...
Page 2
... Signal Contacts For low level current or non-energized testing, connectors are applied to test boards with 2, 2 NOTE ounce thick copper power planes. Circuit carried on 2 commoned 2 ounce layers. For higher current testing, connectors are applied to test boards with 4, 2 ounce thick copper power planes ...
Page 3
... Meets visual requirem ents. ELECTRICAL Power contacts illiohm s m axim um initial illiohm s m axim um change. Signal contacts illiohm s m axim um initial illiohm s m axim um change. 1.6 m illiohm s average of the m axim um values, end of life. 1000 m egohm s m inim um for both signal and power contacts. ...
Page 4
... Measure force necessary to unm ate specim ens axim um rate of 12 per m inute. Tyco Electronics 109-41. Measure force necessary to correctly apply a specim PCB axim um rate of 12 per m inute. Tyco Electronics 109-30-1. Measure force necessary to rem ove a correctly applied specim en from its PCB axim um rate of 12 per m inute ...
Page 5
... Power contacts: Apply axial force pin contacts in the unm ating direction axim um rate of 2. per m inute and hold for 5 seconds. Apply axial force pin contacts in the m ating direction axim um rate of 2. per m inute and hold for 5 seconds. ...
Page 6
... Condition 3, Test Tim e Condition C. Subject m ated specim ens for 500 hours. EIA-364-65, Class IIA (4 gas). Subject specim ens to environm ental Class IIA for 20 days (10 days unm ated followed by 10 days m ated). EIA-364-91. Subject unm ated specim ens to dust contam ination #1 (benign) for 1 hour at an airflow of 1000 cfm ...
Page 7
... Precondition specimens with 10 durability cycles. (g) Power only in housing, signal only in housing, and signal and power in housing. (h) Measure LLCR after 10 days unmated exposure. Rev B Test Group ( 6(b) 7(c) Test Sequence ( 2,4,6 3,7 2,4 2,4,6,8 10 2,6 3,7 3(f), 2(g) 8( 3(f)( Figure 4 108-2325 2,4 3( ...
Page 8
... Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test groups and 10 shall each consist ated plugs and receptacles. Test group 2 shall consist ated plugs and receptacles: 5 plugs fully loaded with power and signal contacts; 5 with power contacts only; and 5 with signal contacts only ...
Page 9
... Rev B Figure 5 Static Load 108-2325 ...