6-1394461-4 TE Connectivity, 6-1394461-4 Datasheet - Page 29
6-1394461-4
Manufacturer Part Number
6-1394461-4
Description
PLUG & SOCKET CONNECTOR, MALE, 1POS
Manufacturer
TE Connectivity
Series
SOLARLOKr
Datasheet
1.1-1579004-2.pdf
(36 pages)
Specifications of 6-1394461-4
Contact Termination
Crimp
No. Of Contacts
1
No. Of Rows
1
Connector Mounting
Cable
Gender
Plug
Contact Material
Copper Alloy
Contact Plating
Silver
Rohs Compliant
Yes
Product Type
Connector
Insulation Diameter (mm [in])
5.50 - 8.00 [.216 - .315]
Type Of Connector
Cable Coupler
Wire Size (mm² [awg])
6.0² [10]
Keying
Neutral
Contact Base Material
Copper Zinc
Contact Finish
Silver Plate
Housing Material
PPO
Housing Color
Black
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Quantity
100
Lead Free Status / Rohs Status
RoHS Compliant part
3.4 DC/AC Converter Receptacle
SOLARLOK Interconnection System
Assembly and Installation Guidelines
1 Place a single wire seal onto the wire and strip wire
2 Crimp the contact using the correct applicator for the wire gauge (# 114-74013)
3 Place O-ring onto the connector housing; push in wire to stop until contact locks into the housing
4 Push seal into the housing
5 Assembly of the cover cap (not available with every version) and mounting in front panel
■
■
■
All specifications subject to change. Consult Tyco Electronics for latest specifications.
(single wire seals are not available with every version).
Required panel mount hole diameter: Diameter 12.5 mm.
The panel thickness must not be under 1.0 mm.
For environmental protection of the unmated connector, use of the covering cap is recommended.
Cover:
Part No. 1394739-1
(continued)
Catalog 889753-3
Revised 6-2008
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 9
27