EZ80L92AZ050SG Zilog, EZ80L92AZ050SG Datasheet - Page 87

IC WEBSERVER 50MHZ 100LQFP

EZ80L92AZ050SG

Manufacturer Part Number
EZ80L92AZ050SG
Description
IC WEBSERVER 50MHZ 100LQFP
Manufacturer
Zilog
Datasheet

Specifications of EZ80L92AZ050SG

Processor Type
eZ80
Features
High Speed, Single-Cycle Instruction-Fetch
Speed
50MHz
Voltage
3.3V
Mounting Type
Surface Mount
Package / Case
100-LQFP
Processor Series
EZ80L92x
Core
eZ80
Data Bus Width
8 bit
Program Memory Size
64 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
24
Number Of Timers
6
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Development Tools By Supplier
eZ80L920210ZCO
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-3878
EZ80L92AZ050SG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EZ80L92AZ050SG
Manufacturer:
Everlight
Quantity:
12 000
Part Number:
EZ80L92AZ050SG
Manufacturer:
Zilog
Quantity:
10 000
PS013014-0107
PRT Count
PRT Clock
(Clock
IOWRN
Output
Value
Timer
CLK
4)
Event Counter
When Timers 0–3 are configured to take their inputs from port input pins PB0 and PB1,
they function as event counters. For event counting, the clock prescaler is bypassed.
The PRT counters decrement on every rising edge of the port pin. The port pins must
be configured as inputs. Due to the input sampling on the pins, the event input signal fre-
quency is limited to one-half the system clock frequency. Input sampling on the port pins
results in the PRT counter being updated on the fifth rising edge of the system clock after
the rising edge occurs at the port pin.
Timer Output
Two of the Programmable Reload Timers (Timers 4 and 5) can be directed to GPIO Port B
output pins (PB4 and PB5, respectively). To enable the Timer Out feature, the GPIO port
pin must be configured for alternate functions. After reset, the Timer Output feature is
disabled by default. The GPIO output pin toggles each time the PRT reaches its end-of-
count value. In CONTINUOUS mode operation, the disabling of the Timer Output feature
results in a Timer Output signal period that is twice the PRT time-out period. Examples of
the Timer Output operation are illustrated in
the GPIO output is assumed to be Low (0) when the Timer Output function is enabled.
Table 31. PRT Timer Out Operation Example
Parameter
PRT Enabled
Reload and Restart Enabled
Figure 21. PRT Timer Output Operation Example
X
I/O Write to TMRx_CTL Enables PRT
3
2
Control Register(s)
TMRx_CTL[0]
TMRx_CTL[1]
Figure 21
1
and
3
Table
Programmable Reload Timers
Product Specification
31. In these examples,
2
Value
1
1
eZ80L92 MCU
1
81

Related parts for EZ80L92AZ050SG