NE1617ADS NXP Semiconductors, NE1617ADS Datasheet - Page 15

no-image

NE1617ADS

Manufacturer Part Number
NE1617ADS
Description
Board Mount Temperature Sensors I2C LOC +/- 2OC AND REM +/- 3OC TS
Manufacturer
NXP Semiconductors
Datasheet

Specifications of NE1617ADS

Full Temp Accuracy
+/- 3 C, +/- 5 C
Package / Case
SSOP-16
Digital Output - Bus Interface
Serial (2-Wire)
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
NE1617ADS,112

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NE1617ADS
Manufacturer:
PERICOM
Quantity:
5
Part Number:
NE1617ADS
Manufacturer:
NXP-Pbf
Quantity:
1 762
Part Number:
NE1617ADS
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
NE1617ADSЈ¬112
Manufacturer:
PH3
Quantity:
2 000
Part Number:
NE1617ADSЈ¬118
Manufacturer:
NXP
Quantity:
2 500
NXP Semiconductors
11. Characteristics
Table 12.
V
[1]
[2]
[3]
[4]
[5]
NE1617A_4
Product data sheet
Symbol
T
T
T
V
V
I
I
t
E
I
I
DD(AV)
DD(stb)
conv
source
bias
DD
res
acc(loc)
acc(rem)
th(UVLO)
th(POR)
f(conv)
= 3.0 V to 3.6 V; T
The value of V
reset. During the time that it is disabled, the temperature that is in the ‘read temperature registers’ will remain at the value that it was
before the ADC was disabled. This is done to eliminate the possibility of reading unexpected false temperatures due to the A/D
converter not working correctly due to low voltage. In case of power-up (rising V
registers’ will be the default value of 0 C. As soon as V
temperatures will be read.
V
V
Address is read at power-up and at start of conversion for all conversions except the fastest rate.
Due to the bias current, any pull-up/pull-down resistors should be
DD
DD
(rising edge) voltage below which the ADC is disabled.
(falling edge) voltage below which the logic is reset.
Parameter
temperature resolution
local temperature accuracy
remote temperature accuracy
undervoltage lockout threshold
voltage
power-on reset threshold
voltage
average supply current
standby supply current
conversion time
conversion rate error
source current
bias current
Characteristics
DD
[1]
below which the internal A/D converter is disabled. This is designed to be a minimum of 200 mV above the power-on
amb
= 0 C to +125 C; unless otherwise specified.
Conditions
T
T
T
T
V
V
conversion rate = 0.25 per second
conversion rate = 2 per second
SMBus inactive
from STOP bit to conversion
complete; both channels
percentage error in programmed
rate
remote sensor
ADD0, ADD1; momentary as the
address is being read
amb
amb
remote
remote
DD
DD
HIGH level
LOW level
supply
supply (falling edge)
= +60 C to +100 C
= 0 C to +125 C
Rev. 04 — 30 July 2009
= +60 C to +100 C
= 40 C to +125 C
DD
[2]
has risen to the value of UVLO, the ADC will function correctly and normal
2 k .
Temperature monitor for microprocessor systems
[3]
DD
), the reading that is stored in the ‘read temperature
[4][5]
Min
1
-
-
-
-
-
1.0
-
-
-
-
-
-
-
30
Typ
-
< 1
< 2
-
-
2.7
-
-
-
3
-
-
100
10
160
NE1617A
© NXP B.V. 2009. All rights reserved.
Max
-
2.95
2.5
70
180
10
170
+30
-
-
-
2
3
3
5
Unit
V
V
ms
%
15 of 27
C
C
C
C
C
A
A
A
A
A
A

Related parts for NE1617ADS