TWR-5/1500-12/250-D48A Murata Power Solutions Inc, TWR-5/1500-12/250-D48A Datasheet
TWR-5/1500-12/250-D48A
Specifications of TWR-5/1500-12/250-D48A
Related parts for TWR-5/1500-12/250-D48A
TWR-5/1500-12/250-D48A Summary of contents
Page 1
... A-Series triples have non-latching output current limiting, input overvoltage shutdown, input reverse-polarity protection, and output overvoltage clamping to protect both the power converters and their loads. All A-Series TWR models are fully EMI characterized and designed to meet UL1950, IEC 950, CSA 950 and EN60950. ERROR AMPLIFIER Technical enquiries email: sales@murata-ps ...
Page 2
... PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE V I OUT OUT Model (V) (mA) ±5 1200 TWR-5/1200-12/250-D48A ±12 ±250 ±5 1500 TWR-5/1500-12/250-D48A ±12 ±250 ±5 1000 TWR-5/1000-15/250-D48A ±15 ±250 ±5 1500 TWR-5/1500-15/250-D48A ±15 ±250 1 Typical @ T = +25°C under nominal line voltage and full-load conditions unless otherwise noted. ...
Page 3
... Performance/Functional Specifications Table is not implied Filtering and Noise Reduction All TWR A-Series 12-15 Watt DC/DC Converters achieve their rated ripple and noise specifications without the use of external input/output capacitors. In critical applications, input/output ripple and noise may be further reduced by installing electrolytic capacitors across the input terminals and/or low- ESR tantalum or electrolytic capacitors across the output terminals ...
Page 4
... Reduce Input/Output Ripple/Noise Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. For Murata Power Solu- tions A-Series TWR 12-15 Watt DC/DC Converters, you should use slow-blow type fuses with values no greater than 2A Murata Power Solutions’ ...
Page 5
... Murata Power Solutions in-house procedure Max. rated temp., 1,000 hours 10 cycles, –55 to +125°C +85°C, 85% humidity, 48 hours Murata Power Solutions in-house procedure +70°C, 500 hours* Murata Power Solutions in-house procedure Per product specification Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_TWR12-15.B01 Page ...