Register 6 (0x06): Global Control 4
Register 7 (0x07): Global Control 5
Note:
September 2009
Bit
7
6
5
4
3
2-0
Bit
7-0
(1)
100BT Rate: 148,800 frames/sec * 67 ms/interval * 1% = 99 frames/interval (approx.) = 0x63
Reserved
Switch MII Half
Duplex Mode
Switch MII
Flow Control
Enable
Switch MII
10BT
Null VID
Replacement
Broadcast
Storm
Protection
Rate
Bit [10:8]
Broadcast
Storm
Protection
Rate
Bit [7:0]
Name
Name
(1)
(1)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
Reserved
Do not change the default values.
=1, Enable MII interface half-duplex mode.
=0, Enable MII interface full-duplex mode.
=1, Enable full duplex flow control on Switch MII interface.
=0, Disable full duplex flow control on Switch MII interface.
=1, The switch interface is in 10Mbps mode
=0, The switch interface is in 100Mbps mode
=1, Will replace NULL VID with port VID (12 bits)
=0, No replacement for NULL VID
This register along with the next register determines how many “64
byte blocks” of packet data are allowed on an input port in a preset
period. The period is 67ms for 100BT or 500ms for 10BT. The
default is 1%.
Description
This register along with the previous register determines how many
“64 byte blocks” of packet data are allowed on an input port in a
preset period. The period is 67ms for 100BT or 500ms for 10BT.
The default is 1%.
53
KSZ8873MLL/FLL/RLL
Default
0
Pin P1LED0 strap
option.
Pull-up(1): Half -duplex
mode
Pull-down(0): Full-
duplex mode
Note: P1LED0 has
internal pull-up.
Pin P1LED1 strap
option.
Pull- up(1): Enable
flow control
Pull-down(0): Disable
flow control
Note: P1LED1 has
internal pull-up.
Pin P3SPD strap
option.
Pull-up(1): Enable
10Mbps
Pull-down(0): Enable
100Mbps
Note: P3SPD has
internal pull-up.
0
000
Default
0x63