2501-480 Time Mark Corporation, 2501-480 Datasheet

no-image

2501-480

Manufacturer Part Number
2501-480
Description
Relay; SSR; Phase Monitor; SPDT; Cur-Rtg 30A; Ctrl-V 480AC; Vol-Rtg 300/28AC/DC; SMT
Manufacturer
Time Mark Corporation
Datasheet

Specifications of 2501-480

Contact Form
SPDT
Current, Rating
30 A
Function
Phase Monitor
Mounting Type
SMD
Relay Type
Solid State
Standards
cULus
Termination
SMT
Voltage, Control
480 VAC
Voltage, Rating
300⁄28 VAC⁄VDC
Lead Free Status / Rohs Status
RoHS Compliant part
l l Monitors for Phase Loss or Reversal,
l l Automatic Reset
l l Heavy Duty Output Contacts
l l UL Listed to U.S. and Canadian
DESCRIPTION
The Models 2500 and 2501 3-Phase Monitors are
designed to continuously monitor the voltages of a 3-phase
power distribution system for abnormal conditions. The
monitors feature solid-state voltage and phase angle
sensing circuits which drive a SPDT electromechanical
output relay. A neutral connection is not required with either
the Model 2500 or 2501. This allows each model to be
connected to any three phase WYE or DELTA configured
power distribution system.
When the correct voltage and phase sequence is applied to
a specified Model 2500, the output relay will not energize.
An under voltage, phase reversal, phase unbalance or
phase loss condition will cause the output relay to
energize, even if regenerated voltage is present. Complete
power loss will not cause Model 2500 to trip.
When the correct voltage and phase sequence is applied to
a specified Model 2501, the output relay will energize. An
under voltage, phase reversal, phase unbalance, or phase
loss condition will cause the output relay to de-energize.
Each option on the Model 2500 or 2501 is adjustable
throughout it’s operating range. The adjustment pots and
L E D indicators for VOLTAGE ADJUST, UNBALANCE
ADJUST and TIME DELAY are mounted on the front of the
unit, for easy access .
Seven versions of both the Model 2500 and the Model 2501
cover voltage ranges from 120 to 600 VAC. All models are
UL Listed to U.S. and Canadian safety standards.
TYPICAL APPLICATION - Motor
Low Voltage or Voltage Unbalance
Safety Standards
3-Phase Monitor
MODEL 2500
MODEL 2501
Shows No Power Applied
SPECIFICATIONS
Model
Nominal AC Voltage
Adjustment Range
Frequency
Unbalance adj
range
Trip Delay adj range
Power Consumption
Repeat Accuracy
Reset Time
Reset Type
Dead Band
Output Contacts
Operating Temp
Humidity Tolerance
Enclosure Material
Weight
Mounting
Agency Approval
DIMENSIONS
2500-120
2501-120
84-114V 146-198V 168-229V 266-361V 290-394V 336-456V 420-570V
120
UL Listed to U.S. and Canadian safety standards
SPDT 30 amps at 28VDC/300VAC 50/60 Hz
5 amps at 480/600VAC 50/60 Hz 0.75 PF
2500-208
2501-208
208
1 to 10 seconds (1 sec increments)
2 to 10% per NEMA specifications
0-97% without condensation
2500-240
2501-240
240
150 msec nominal
± 1% of full scale
4.5W per phase
2% of full scale
- 4º to +131º F
ABS plastic
2 lbs. 5 oz.
Automatic
50/60 Hz
2500-380
2501-380
Surface
380
2500-415
2501-415
415
2500-480
2501-480
480
2500-600
2501-600
600