Specifications of AT49BV320AT-70TI

Cell Type
NOR
Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP-I
Program/erase Volt (typ)
2.65 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.65V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
25mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant
Figure 1. Data Polling Algorithm
(Configuration Register = 00)
Notes:
10
NO
1. VA = Valid address for programming. During a sec-
2. I/O7 should be rechecked even if I/O5 = “1”
AT49BV32XA(T)
Successful, Write
tor erase operation, a valid address is any sector
address within the sector being erased. During
chip erase, a valid address is any non-protected
sector address.
because I/O7 may change simultaneously with
I/O5.
Read I/O7 - I/O0
Read I/O7 - I/O0
Program/Erase
I/O3, I/O5 = 1?
Operation Not
Exit Command
I/O7 = Data?
Product ID
I/O7 = Data?
Addr = VA
Addr = VA
START
NO
YES
NO
YES
YES
Program/Erase
Successful,
Read Mode
Operation
Device in
Figure 2. Data Polling Algorithm
(Configuration Register = 01)
Note:
NO
1. VA = Valid address for programming. During a sec-
Successful, Write
tor erase operation, a valid address is any sector
address within the sector being erased. During
chip erase, a valid address is any non-protected
sector address.
Read I/O7 - I/O0
Read I/O7 - I/O0
Read I/O7 - I/O0
Program/Erase
I/O3, I/O5 = 1?
Operation Not
Exit Command
Toggle Bit =
Toggle Bit =
Product ID
Toggle?
Toggle?
START
Twice
YES
YES
YES
NO
NO
Successful, Write
Product ID Exit
Program/Erase
Operation
Command
3308D–FLASH–5/03