HD64F2168VTE33 Renesas Electronics America, HD64F2168VTE33 Datasheet - Page 439

no-image

HD64F2168VTE33

Manufacturer Part Number
HD64F2168VTE33
Description
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HD64F2168VTE33

Cpu Family
H8S
Device Core Size
16/32Bit
Frequency (max)
33MHz
Interface Type
I2C/IrDA/SCI
Program Memory Type
Flash
Program Memory Size
256KB
Total Internal Ram Size
40KB
# I/os (max)
106
Number Of Timers - General Purpose
5
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
On-chip Adc
8-chx10-bit
On-chip Dac
2-chx8-bit
Instruction Set Architecture
CISC
Operating Temp Range
-20C to 75C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
144
Package Type
TQFP
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2168VTE33
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F2168VTE33V
Manufacturer:
Renesas
Quantity:
8 400
Part Number:
HD64F2168VTE33V
Manufacturer:
RENESAS
Quantity:
112
Part Number:
HD64F2168VTE33V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
No
No
No
Figure 14.16 Sample Multiprocessor Serial Reception Flowchart (1)
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Set MPIE bit in SCR to 1
Read RDRF flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
All data received?
FER ∨ ORER = 1
This station’s ID?
FER ∨ ORER = 1
Start reception
Initialization
RDRF = 1
RDRF = 1
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Error processing
[3]
[1]
[2]
(Continued on
next page)
[4]
[5]
[1] SCI initialization:
[2] ID reception cycle:
[3] SCI status check, ID reception and
[4] SCI status check and data reception:
[5] Receive error processing and break
Legend
∨ : Logical add (OR)
The RxD pin is automatically designated
as the receive data input pin.
Set the MPIE bit in SCR to 1.
comparison:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR and compare it with this
station’s ID.
If the data is not this station’s ID, set the
MPIE bit to 1 again, and clear the RDRF
flag to 0.
If the data is this station’s ID, clear the
RDRF flag to 0.
Read SSR and check that the RDRF
flag is set to 1, then read the data in
RDR.
detection:
If a receive error occurs, read the ORER
and FER flags in SSR to identify the
error. After performing the appropriate
error processing, ensure that the ORER
and FER flags are all cleared to 0.
Reception cannot be resumed if either
of these flags is set to 1.
In the case of a framing error, a break
can be detected by reading the RxD pin
value.
Rev. 3.00, 03/04, page 397 of 830

Related parts for HD64F2168VTE33