SI3019-F-FT Silicon Laboratories Inc, SI3019-F-FT Datasheet - Page 82

no-image

SI3019-F-FT

Manufacturer Part Number
SI3019-F-FT
Description
IC VOICE DAA GCI/PCM/SPI 16TSSOP
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheets

Specifications of SI3019-F-FT

Package / Case
16-TSSOP
Function
Data Access Arrangement (DAA)
Interface
GCI, PCM, SPI
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Includes
Line Voltage Monitor, Loop Current Monitor, Overload Detection, Parallel Handset Detection, Polarity Reversal Detection, TIP and
Product
Modem Chip
Supply Voltage (min)
3 V
Supply Current
8.5 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3019-F-FTR
Manufacturer:
SiliconL
Quantity:
5 000
Part Number:
SI3019-F-FTR
Manufacturer:
SiliconLa
Quantity:
872
Part Number:
SI3019-F-FTR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si3050
Register 31. DAA Control 5
Reset settings = 0010_0000
82
6:5
Bit
7
4
3
2
1
0
Name
Type
Bit
Reserved Always write these bits to zero.
Reserved Always write these bits to zero.
FOH[1:0] Fast Off-Hook Selection.
Name
OHS2
FULL
LVFD
FILT
FULL
R/W
Full Scale Transmit and Receive Mode.
0 = Default.
1 = Transmit/receive full scale.
This bit changes the full scale of the ADC and DAC from 0 dBm min to +3.2 dBm into a 600 Ω
load (or 1 dBV into all reference impedances). When this bit is set, the DCV[1:0] bits
(Register 26) should be set to all 1s. The MINI[1:0] bits also should be set to all 0s. This ensures
correct operation of the full scale mode.
These bits determine the length of the off-hook counter. The default setting is 128 ms.
00 = 512 ms
01 = 128 ms
10 = 64 ms
11 = 8 ms
On-Hook Speed 2.
Filter Pole Selection.
0 = The receive path has a low –3 dBFS corner at 5 Hz.
1 = The receive path has a low –3 dBFS corner at 200 Hz.
Line Voltage Force Disable (Si3019 line-side only).
0 = Normal operation.
1 = The circuitry that forces the LVS register (Register 29) to all 0s at 3 V or less is disabled. The
LVS register may display unpredictable values at voltages between 0 to 2 V. All 0s are displayed
if the line voltage is 0 V.
This bit, in combination with the OHS bit (Register 16) and the SQ[1:0] bits on-hook speeds
specified are measured from the time the OH bit is cleared until loop current equals zero.
OHS
D7
0
0
1
OHS2
D6
0
1
X
FOH[1:0]
RW
SQ[1:0]
D5
00
00
11
Rev. 1.2
D4
0
26 ms ±10% (meets Australia spark quenching spec)
Mean On-Hook Speed
Less than 0.5 ms
3 ms ±10% (meets ETSI standard)
Function
OHS2
R/W
D3
D2
0
FILT
R/W
D1
LVFD
R/W
D0

Related parts for SI3019-F-FT