SI3019-F-FT Silicon Laboratories Inc, SI3019-F-FT Datasheet - Page 90

no-image

SI3019-F-FT

Manufacturer Part Number
SI3019-F-FT
Description
IC VOICE DAA GCI/PCM/SPI 16TSSOP
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheets

Specifications of SI3019-F-FT

Package / Case
16-TSSOP
Function
Data Access Arrangement (DAA)
Interface
GCI, PCM, SPI
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Includes
Line Voltage Monitor, Loop Current Monitor, Overload Detection, Parallel Handset Detection, Polarity Reversal Detection, TIP and
Product
Modem Chip
Supply Voltage (min)
3 V
Supply Current
8.5 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3019-F-FTR
Manufacturer:
SiliconL
Quantity:
5 000
Part Number:
SI3019-F-FTR
Manufacturer:
SiliconLa
Quantity:
872
Part Number:
SI3019-F-FTR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si3050
Register 42. GCI Control
Reset settings = 0000_0000
90
Bit
7:4
3:2
1
0
Name
Type
Bit
Reserved Read returns zero.
GCIF[1:0] GCI Data Format.
Name
B2D
B1D
D7
00 = A-Law.
01 = µ-Law.
10 = 8-bit linear. The top 8-bits of the 16-bit linear signal are transferred, and the bottom 8-bits
are discarded.
11 = 16-bit linear. B1 and B2 channels are used for the 16-bits of data. Regardless of whether
the DAA is set to transmit and receive in the B1 or B2 channel, both channels are used to
send and receive the 16-bit linear data.
Channel B2 Enable.
0 = Channel B2 transfers are disabled.
1 = Channel B2 transfers are enabled. If 16-bit linear data format is chosen, disabling the B2
channel results in only the top 8 bits of line data being sent and received in the B1 channel.
Channel B1 Enable.
0 = Channel B1 transfers are disabled.
1 = Channel B1 transfers are enabled. If 16-bit linear data format is chosen, disabling the B1
channel results in only the bottom 8 bits of line data being sent and received in the B2 chan-
nel.
D6
D5
Rev. 1.2
D4
Function
D3
GCIF[1:0]
R/W
D2
B2D
R/W
D1
B1D
R/W
D0