Specifications of PEB 3081 H V1.4

Function
S / T Bus Interface Transceiver
Interface
IOM-2, ISDN, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
D-Channel Access Control, Monitor Channel Handler
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3081HV1.4XT
PEB3081HV14XP
SP000007583
SP000007584
• To control this handshake procedure a collision detection mechanism is implemented
• Monitor data will be transmitted repeatedly until its reception is acknowledged or the
• Two frames with the MX bit in the inactive state indicates the end of a message
• Transmission and reception of monitor messages can be performed simultaneously.
3.7.3.2
In case the SBCX-X does not detect identical monitor messages in two successive
frames, transmission is not aborted. Instead the SBCX-X will wait until two identical bytes
are received in succession.
A transmission is aborted of the SBCX-X if
• an error in the MR handshaking occurs
• a collision on the IOM-2 bus of the MONITOR data or MX bit occurs
• the transmission time-out timer expires
A reception is aborted by the device if
• an error in the MX handshaking occurs or
• an abort request from the opposite device occurs
MX/MR Treatment in Error Case
In the master mode the MX/MR bits are under control of the microcontroller through MXC
or MRC, respectively. An abort is indicated by an MAB interrupt or MER interrupt,
respectively.
In the slave mode the MX/MR bits are under control of the device. An abort is always
indicated by setting the MX/MR bit inactive for two or more IOM-2 frames. The controller
must react with EOM.
Figure 55
an example for an abort requested by the transmitter and
for a successful transmission.
Data Sheet
in the transmitter. This is done by making a collision check per bit on the transmitted
MONITOR data and the MX bit.
transmission time-out timer expires.
(EOM).
This feature is used by the SBCX-X to send back the response before the
transmission from the controller is completed (the SBCX-X does not wait for EOM
from controller).
shows an example for an abort requested by the receiver,
Error Treatment
101
Description of Functional Blocks
Figure 57
shows an example
Figure 56
PEB 3081
2003-02-04
SBCX-X
shows

Related parts for PEB 3081 H V1.4