PEB 3081 H V1.4 Infineon Technologies, PEB 3081 H V1.4 Datasheet - Page 51

no-image

PEB 3081 H V1.4

Manufacturer Part Number
PEB 3081 H V1.4
Description
IC S-BUS INTERFACE EXT MQFP44
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB 3081 H V1.4

Function
S / T Bus Interface Transceiver
Interface
IOM-2, ISDN, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
D-Channel Access Control, Monitor Channel Handler
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3081HV1.4XT
PEB3081HV14XP
SP000007583
SP000007584
Figure 27
3.3.10
The SBCX-X provides test and diagnostic functions for the S/T interface:
Note: For more details please refer to the application note “Test Function of new S-
– The internal local loop (internal Loop A) is activated by a C/I command ARL or by
– The external local loop (external Loop A) is activated in the same way as the internal
– In remote line loop (RLP) received data is looped back to the S/T interface. The D-
Data Sheet
setting the bit LP_A (Loop Analog) in the TR_CMD register if the layer-1 statemachine
is disabled.
The transmit data of the transmitter is looped back internally to the receiver. The data
of the IOM-2 input B- and D-channels are looped back to the output B- and D-
channels.
The S/T interface level detector is enabled, i.e. if a level is detected this will be
reported by the Resynchronization Indication (RSY) but the loop function is not
affected.
Depending on the DIS_TX bit in the TR_CONF2 register the internal local loop can be
transparent or non transparent to the S/T line.
local loop described above. Additionally the EXLP bit in the TR_CONF0 register has
to be programmed and the loop has to be closed externally as described in
The S/T interface level detector is disabled.
This allows complete system diagnostics.
channel information received from the line card is transparently forwarded to the
output IOM-2 D-channel. The output B-channel information on IOM-2 is fixed to ‘FF’
while this test loop is active. The remote loop is programmable in TR_CONF2.RLP.
Transceiver family”
Test Functions
Disabling of S/T Transmitter
TR_CONF0.DIS_TR
51
TR_CONF2.DIS_TX
Description of Functional Blocks
’1’
’0’
PEB 3081
Figure
2003-02-04
SBCX-X
28.
H