Specifications of PEB 3081 H V1.4

Function
S / T Bus Interface Transceiver
Interface
IOM-2, ISDN, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
D-Channel Access Control, Monitor Channel Handler
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3081HV1.4XT
PEB3081HV14XP
SP000007583
SP000007584
SBCX-X
PEB 3081
Description of Functional Blocks
F5 Unsynchronized
Any signal except INFO 2 or 4 detected on the S/T interface.
F6 Synchronized
The receiver has synchronized and detects INFO 2. INFO 3 is transmitted to
synchronize the NT.
F7 Activated
The receiver has synchronized and detects INFO 4. All user channels are now conveyed
transparently to the IOM-2 interface.
To transfer user channels transparently to the S/T interface either the command AR8 or
AR10 has to be issued and TR_STA.FSYN must be “1” (signal from remote side must
be synchronous).
F8 Lost Framing
The receiver has lost synchronization in the states F6 or F7 respectively.
Unconditional States
Loop A Closed (internal or external)
The SBCX-X loops back the transmitter to the receiver and activates by transmission of
INFO 3. The receiver has not yet synchronized.
For a non transparent internal loop the DIS_TX bit of register TR_CONF2 has to be set
to ’1’.
Loop A Activated (internal or external)
The receiver has synchronized to INFO 3. Data may be sent. The indication “AIL” is
output to indicate the activated state. If the loop is closed internally and the S/T line
awake detector detects any signal on the S/T interface, this is indicated by “RSY”.
Test Mode - SSP
Single alternating pulses are transmitted to the S/T-interface resulting in a frequency of
the fundamental mode of 2 kHz.
Test Mode - SCP
Continuous alternating pulses are transmitted to the S/T-interface resulting in a
frequency of the fundamental mode of 96 kHz.