PEB 3081 H V1.4 Infineon Technologies, PEB 3081 H V1.4 Datasheet - Page 68

no-image

PEB 3081 H V1.4

Manufacturer Part Number
PEB 3081 H V1.4
Description
IC S-BUS INTERFACE EXT MQFP44
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB 3081 H V1.4

Function
S / T Bus Interface Transceiver
Interface
IOM-2, ISDN, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
D-Channel Access Control, Monitor Channel Handler
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3081HV1.4XT
PEB3081HV14XP
SP000007583
SP000007584
SBCX-X
PEB 3081
Description of Functional Blocks
3.5.2.2
States (LT-S)
G1 Deactivated
The transceiver is not transmitting. There is no signal detected on the S/T interface, and
no activation command is received in the C/I channel. The clocks are deactivated if
MODE1.CFS is set to 1. Activation is possible from the S/T interface and from the IOM-
2 interface.
G2 Pending Activation
As a result of an INFO 0 detected on the S/T line or an ARD command, the transceiver
begins transmitting INFO 2 and waits for reception of INFO 3. The timer to supervise
reception of INFO 3 is to be implemented in software. In case of an ARL command, loop
2 is closed.
G3 Activated
Normal state where INFO 4 is transmitted to the S/T-interface. The transceiver remains
in this state as long as neither a deactivation nor a test mode is requested, nor the
receiver looses synchronism.
When receiver synchronism is lost, INFO 2 is sent automatically. After reception of
INFO 3, the transmitter keeps on sending INFO 4.
G2 Lost Framing
This state is reached when the transceiver has lost synchronism in the state G3
activated.
G4 Pending Deactivation
This state is triggered by a deactivation request DR. It is an unstable state: indication DI
(state “G4 Wait for DR.”) is issued by the transceiver when:
either INFO 0 is received for a duration of 16 ms,
or an internal timer of 32 ms expires.
G4 Wait for DR
Final state after a deactivation request. The transceiver remains in this state until DC is
issued.
Unconditional States
Test mode - SSP
Single alternating pulses are sent on the S/T-interface.
Data Sheet
68
2003-02-04

Related parts for PEB 3081 H V1.4