Description
IC S-BUS INTERFACE EXT MQFP44
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB 3081 H V1.4

Function
S / T Bus Interface Transceiver
Interface
IOM-2, ISDN, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
D-Channel Access Control, Monitor Channel Handler
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3081HV1.4XT
PEB3081HV14XP
SP000007583
SP000007584
Test mode - SCP
Continuous alternating pulses are sent on the S/T-interface.
3.5.2.3
Command
Deactivation
Request
Reset
Send Single Pulses
Send Continuous
Pulses
Activation Request
Activation Request
Loop
Deactivation
Confirmation
Indication
Timing
Receiver not
Synchronous
Activation Request
Illegal Code
Violation
Data Sheet
C/I Codes (LT-S)
AR
Abbr.
DR
RES
SSP
SCP
ARL
DC
Abbr.
TIM
RSY
AR
CVR
Code
0000
0001
0010
0011
1000
1010
1111
Code
0000
0100
1000
1011
Send Continuous Pulses.
Remark
DR - Deactivation Request. Initiates a complete
deactivation from the exchange side by
transmitting INFO 0.
Reset of state machine. Transmission of
INFO 0. No reaction to incoming infos. RES is
an unconditional command.
Send Single Pulses.
Activation Request. This command is used to
start an exchange initiated activation.
Activation request loop. The transceiver is
requested to operate an analog loop-back close
to the S/T-interface.
Deactivation Confirmation. Transfers the
transceiver into a deactivated state in which it
can be activated from a terminal (detection of
INFO 0 enabled).
Remark
Interim indication during activation procedure in
G1.
Receiver is not synchronous
INFO 0 received from terminal. Activation
proceeds.
Illegal code violation received. This function
has to be enabled in TR_CONF0.EN_ICV.