A3935 Allegro MicroSystems, Inc., A3935 Datasheet - Page 7
A3935
Manufacturer Part Number
A3935
Description
Three-Phase Power MOSFET Controller
Manufacturer
Allegro MicroSystems, Inc.
Datasheet
1.A3935.pdf
(16 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
A3935KED
Manufacturer:
Allegro MicroSystems, LLC
Quantity:
10 000
Company:
Part Number:
A3935KED-T
Manufacturer:
Allegro MicroSystems, LLC
Quantity:
10 000
Company:
Part Number:
A3935KEDTR
Manufacturer:
Allegro MicroSystems, LLC
Quantity:
10 000
Company:
Part Number:
A3935KEDTR-T
Manufacturer:
Allegro MicroSystems, LLC
Quantity:
10 000
Company:
Part Number:
A3935KJP
Manufacturer:
Allegro MicroSystems, LLC
Quantity:
10 000
Company:
Part Number:
A3935KLQTR
Manufacturer:
Allegro
Quantity:
824
Part Number:
A3935KLQTR
Manufacturer:
ALLEGRO/雅丽高
Quantity:
20 000
Part Number:
A3935KLQTR-T
Manufacturer:
ALLEGRO/雅丽高
Quantity:
20 000
ELECTRICAL CHARACTERISTICS:
V
Characteristics
Fault Logic
VDD Undervoltage
VDD Undervoltage Hysteresis
OVSET Operating Volt. Range
OVSET Calibrated Volt. Range
OVSET Input Current Range
VBAT Overvoltage Range
VBAT Overvoltage
VBAT Overvoltage Hysteresis
VBAT Overvoltage Gain Constant
VBAT Undervoltage
VBAT Undervoltage Hysteresis
VREG Undervoltage
VDSTH Input Range
VDSTH Input Current
Short-to-Ground Threshold
Short-to-Battery Threshold
V
V
V
Thermal Shutdown Temp.
Thermal Shutdown Hysteresis
NOTES: Typical Data and Typical Characteristics are for design information only.
DRAIN
DRAIN
DRAIN
www.allegromicro.com
DD
= 4.75 V to 5.25 V, ENABLE = 22.5 kHz, 50% Duty Cycle, Two Phases Active.
/Open Bridge Threshold Volt.
/Open Bridge Oper. Range
/Open Bridge Current
Negative current is defined as coming out of (sourcing) the specified device terminal.
Symbol
V
V
V
V
V
V
K
V
V
V
V
I
V
I
V
V
V
V
SET(ov)
I
VDRAIN
BDGO(th)
REG(uv)
SET(ov)
SET(ov)
BAT(ov)
BAT(ov)
BAT(ov)
BAT(uv)
STG(th)
STB(th)
DSTH
DD(uv)
DRAIN
BAT(ov)
BAT(uv)
DSTH
T
DD(uv)
T
J
J
unless otherwise noted at T
Conditions
Decreasing V
V
0 V < V
Increasing V
Percent of V
V
Decreasing V
Percent of V
Decreasing V
V
With a high-side driver “on”, as V
V
With a low-side driver “on”, as V
V
7 V < V
7 V < V
If V
DD(recovery)
BAT(ov)
DSTH
DRAIN
SX
DRAIN
- V
> 0.8 V
- V
= (K
LSS
SET(ov)
BAT
BAT
< V
SX
> V
- V
< 40 V
< 40 V
BAT(ov)
> V
BDGOTH
BAT(ov)
BAT(uv)
BAT
< 2.5 V
DD(uv)
STB
DD
BAT
REG
STG
, V
x V
causes a fault
SET(ov)
value set by V
causes a fault
then a bridge fault occurs
SET(ov)
= 0 V
) + V
BAT(ov)
J
SX
SET(ov)
= -40°C to +150°C, V
SX
increases,
[0]
decreases,
MOSFET CONTROLLER
THREE-PHASE POWER
V
V
DSTH
DSTH
19.4
19.4
Min
100
-1.0
-0.3
160
3.8
9.0
5.0
8.0
9.9
0.5
1.0
7.0
40
0
0
–
0
BAT
-0.3 – V
-0.3 – V
= 7 V to 16 V,
22.4
5.25
Typ
170
12
10
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Limits
V
DSTH
DSTH
BAT
Max
+1.0
25.4
11.1
300
100
180
V
3.0
4.3
2.5
5.5
3.0
1.0
40
15
12
13
–
DD
+2.0
+0.2
+0.2
3935
Units
V/V
mV
mA
µA
µA
°C
°C
%
%
V
V
V
V
V
V
V
V
V
V
V
V
7