MT9171 Mitel Networks, MT9171 Datasheet - Page 11

no-image

MT9171

Manufacturer Part Number
MT9171
Description
ISO2-CMOS ST-BUS FAMILY Digital Subscriber Interface Circuit Digital Network Interface Circuit
Manufacturer
Mitel Networks
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9171AE
Manufacturer:
MITEL
Quantity:
5 510
Part Number:
MT9171AE
Manufacturer:
SEC
Quantity:
5 510
Part Number:
MT9171AN
Manufacturer:
MITEL
Quantity:
27
Part Number:
MT9171AN
Manufacturer:
ZARLINK
Quantity:
6 000
Part Number:
MT9171AN
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
MT9171AN1
Manufacturer:
ZARLINK
Quantity:
230
Part Number:
MT9171ANR1
Manufacturer:
ZARLINK
Quantity:
230
Part Number:
MT9171ANR1
0
Part Number:
MT9171AP
Manufacturer:
ZARLINK
Quantity:
6 000
Part Number:
MT9171AP
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
MT9171AP1
Manufacturer:
ZARLINK
Quantity:
1 500
Advance Information
information over the line at 8, 16 or 64 kbit/s (by
using the DINB feature). The information passes
transparently through the DNIC and is transmitted to
or received from the line at the bit rate selected in
the Control Register.
If the bit rate is 80 kbit/s, only D0 is transmitted and
received. At 160 kbit/s, D0 and D1 are transmitted
and received. When the DINB bit is set in the Control
Register the entire D-channel is transmitted and
received in the B1-channel timeslot.
The C-channel is used for transferring control and
status information between the DNIC and the
system. The Control and Diagnostics Registers are
accessed through the C-channel. They contain
information to control the DNIC and carry out the
diagnostics as well as the HK bit to be transmitted on
the line as described in Tables 4 and 5. Bits 0 and 1
of the C-channel select between the Control and
Notes:
Bit
0
1
2
3
4
5
6
7
Suggested use of ATTACK:
-At 160 kbit/s full convergence requires 850 ms with ATTACK held high for the first 240 frames or 30 ms.
-At 80 kbit/s full convergence requires 1.75 s with ATTACK held high for the first 480 frames or 60 ms.
When bits 4-7 of the Control Register are all set to one, the DNIC operates in one of the default modes as defined in Table 4a,
depending upon the status of bit-3.
Reg Sel-1
Reg Sel-1
Reg Sel-2
ATTACK
PSEN
TxHK
DINB
bit 0
Name
DRR
BRS
Reg Sel-2
bit 1
Register Select-1. Must be set to ’0’ to select the Control Register.
Register Select-2. Must be set to ’0’ to select the Control Register.
Diagnostics Register Reset. Writing a "0" to this bit will cause a diagnostics register reset
to occur coincident with the next frame pulse as in the MT8972A. When this bit is a logic
"1", the Diagnostics Register will not be reset.
Bit Rate Select. When set to ’0’ selects 80 kbit/s. When set to ’1’, selects 160 kbit/s.
D-Channel in B Timeslot. When ’0’, the D-channel bits (D0 or D0 and D1) corresponding
to the selected bit rate (80 or 160 kbit/s) are transmitted during the normal D-channel bit
times. When set to ’1’, the entire D-channel (D0-D7) is transmitted during the B1-channel
timeslot on the line providing a 64 kbit/s D-channel link.
Prescrambler/Deprescrambler Enable. When set to ’1’, the data prescrambler and
deprescrambler are enabled. When set to ’0’, the data prescrambler and deprescrambler
are disabled.
Convergence Speedup. When set to ’1’, the echo canceller will converge to the reflection
coefficient much faster. Used on power-up for fast convergence. When ’0’, the echo
canceller will require the normal amount of time to converge to a reflection coefficient.
Transmit Housekeeping. When set to ’0’, logic zero is transmitted over the line as
Housekeeping Bit. When set to ’1’, logic one is transmitted over the line as
Housekeeping Bit.
DRR
bit 2
Table 4. Control Register
bit 3
BRS
DINB
bit 4
Diagnostics Register. If these bits are 0, 0 then the
C-channel information is written to the Control
Register (Table 4). If they are 0, 1 the C-
written to the Diagnostics Register (Table 5).
The Diagnostics Register Reset bit (bit 2) of the
Control Register determines the reset state of the
Diagnostics Register. If, on writing to the Control
Register, this bit is set to logic “0”, the Diagnostics
Register will be reset coincident with the frame
pulse. When this bit is logic “1”, the Diagnostics
Register will not be reset.
diagnostic features, the Diagnostics Register must
be continuously written to. The output C-channel
sends status information from the Status Register to
the system along with the received HK bit as shown
in Table 6.
In MOD mode, the CD port is no longer an ST-BUS
but is a serial bit stream operating at the bit rate
Default Mode Selection (Refer to Table 4a)
Description
PSEN
bit 5
ATTACK
bit 6
In order to use the
MT9171/72
TxHK
bit 7
c
hannel is
9-143

Related parts for MT9171