LM35-MWC National Semiconductor Corporation, LM35-MWC Datasheet

LM35-MWC
Related parts for LM35-MWC
LM35-MWC Summary of contents
Page 1
... The LM35 is rated to operate over a −55˚ to +150˚C temperature range, while the LM35C is rated for a −40˚ to +110˚C range (−10˚ with improved accuracy). The LM35 series is available pack- Typical Applications DS005516-3 FIGURE 1 ...
Page 2
... Small Outline Molded Package DS005516-21 N. Connection Top View Order Number LM35DM See NS Package Number M08A TO-220 Plastic Package* DS005516-24 *Tab is connected to the negative pin (GND). Note: The LM35DT pinout is different than the discontinued LM35DP. Order Number LM35DT See NS Package Number TA03F 2 ...
Page 3
... Vapor Phase (60 seconds) Infrared (15 seconds) +35V to −0.2V ESD Susceptibility (Note 11) +6V to −1.0V Specified Operating Temperature Range (Note 2) LM35, LM35A −60˚C to +180˚C LM35C, LM35CA −60˚C to +150˚C LM35D −65˚C to +150˚C −65˚C to +150˚C 300˚C ...
Page 4
... LM35 and LM35A; −40˚ =50 µA, in the circuit of Figure 2 . These specifications also apply from +2˚ LOAD resistor. 4 LM35C, LM35D Tested Design Units Typical Limit Limit (Max.) (Note 4) (Note 5) ± ± ...
Page 5
Typical Performance Characteristics Thermal Resistance Junction to Air DS005516-25 Thermal Response in Stirred Oil Bath DS005516-28 Quiescent Current vs. Temperature (In Circuit of Figure 2 .) DS005516-31 Thermal Time Constant DS005516-26 Minimum Supply Voltage vs. Temperature DS005516-29 Accuracy vs. Temperature ...
Page 6
... Alternatively, the LM35 can be mounted inside a sealed-end metal tube, and can then be dipped into a bath or screwed into a threaded hole in a tank. As with any IC, the LM35 and accompanying wiring and circuits must be kept insulated and dry, to avoid leakage and corrosion. This is especially true if the circuit may operate at cold temperatures where conden- sation can occur ...
Page 7
... FIGURE 4. LM35 with R-C Damper CAPACITIVE LOADS Like most micropower circuits, the LM35 has a limited ability to drive heavy capacitive loads. The LM35 by itself is able to drive 50 pf without special precautions. If heavier loads are anticipated easy to isolate or decouple the load with a resistor; see Figure you can improve the tolerance of capacitance with a series R-C damper from output to ground ...
Page 8
Typical Applications (Continued) FIGURE 10. Fahrenheit Thermometer FIGURE 13. Temperature To Digital Converter (Serial Output) (+128˚C Full Scale) FIGURE 14. Temperature To Digital Converter (Parallel TRI-STATE Standard Data Bus to µP Interface) (128˚C Full Scale) www.national.com FIGURE 11. Centigrade Thermometer ...
Page 9
... B B Trim R for V =1.955V C C Trim R for V =0.075V + 100mV/˚ ambient Example, V =2.275V at 22˚C A FIGURE 15. Bar-Graph Temperature Display (Dot Mode) FIGURE 16. LM35 With Voltage-To-Frequency Converter And Isolated Output (2˚C to +150˚ 1500 Hz) 9 DS005516-16 DS005516-15 www.national.com ...
Page 10
Block Diagram www.national.com DS005516-23 10 ...
Page 11
... Physical Dimensions inches (millimeters) unless otherwise noted TO-46 Metal Can Package (H) Order Number LM35H, LM35AH, LM35CH, LM35CAH, or LM35DH NS Package Number H03H SO-8 Molded Small Outline Package (M) Order Number LM35DM NS Package Number M08A 11 www.national.com ...
Page 12
... Physical Dimensions www.national.com inches (millimeters) unless otherwise noted (Continued) Power Package TO-220 (T) Order Number LM35DT NS Package Number TA03F 12 ...
Page 13
... National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications. inches (millimeters) unless otherwise noted (Continued) TO-92 Plastic Package (Z) Order Number LM35CZ, LM35CAZ or LM35DZ NS Package Number Z03A 2. A critical component is any component of a life ...