w79e532 Winbond Electronics Corp America, w79e532 Datasheet - Page 11

no-image

w79e532

Manufacturer Part Number
w79e532
Description
8-bit Microcontroller
Manufacturer
Winbond Electronics Corp America
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
w79e532A40FL
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
Part Number:
w79e532A40PL
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
PD:
IDL:
Timer Control
TF1:
TR1:
TF0:
TR0:
IE1:
IT1:
IE0:
IT0:
Timer Mode Control
GATE: Gating control: When this bit is set, Timer/counter x is enabled only while INTx pin is high and
Setting this bit causes the W79E(L)532 to go into the POWER DOWN mode. In this mode all
the
clocks are stopped and program execution is frozen.
Setting this bit causes the W79E(L)532 to go into the IDLE mode. In this mode the clocks to
the
CPU are stopped, so program execution is frozen. But the clock to the serial, timer and
interrupt blocks is not stopped, and these blocks continue operating.
Timer 1 overflow flag: This bit is set when Timer 1 overflows. It is cleared automatically when
the program does a timer 1 interrupt service routine. Software can also set or clear this bit.
Timer 0 overflow flag: This bit is set when Timer 0 overflows. It is cleared automatically when
the program does a timer 0 interrupt service routine. Software can also set or clear this bit.
Interrupt 1 edge detect: Set by hardware when an edge/level is detected on INT1 . This bit is
cleared by hardware when the service routine is vectored to only if the interrupt was edge
triggered. Otherwise it follows the pin.
Interrupt 1 type control: Set/cleared by software to specify falling edge/ low level triggered
external inputs.
Interrupt 0 edge detect: Set by hardware when an edge/level is detected on INT0 . This bit is
cleared by hardware when the service routine is vectored to only if the interrupt was edge
triggered. Otherwise it follows the pin.
Interrupt 0 type control: Set/cleared by software to specify falling edge/ low level triggered
external inputs.
TRx control bit is set. When cleared, Timer x is enabled whenever TRx control bit is set.
Timer 1 run control: This bit is set or cleared by software to turn timer/counter on or off.
Timer 0 run control: This bit is set or cleared by software to turn timer/counter on or off.
Mnemonic: TCON
Mnemonic: TMOD
Bit:
Bit:
GATE
TF1
7
7
C T
TR1
6
6
/
TIMER1
TF0
M1
5
5
- 11 -
TR0
M0
4
4
Publication Release Date: November 21, 2005
GATE
IE1
W79E532/W79L532
3
3
Address: 88h
Address: 89h
C T
IT1
2
2
/
TIMER0
IE0
M1
1
1
Revision A5
IT0
M0
0
0

Related parts for w79e532