a10657-01 Hamamatsu Photonics, K.K.,, a10657-01 Datasheet

no-image

a10657-01

Manufacturer Part Number
a10657-01
Description
Microwell Slide
Manufacturer
Hamamatsu Photonics, K.K.,
Datasheet
GSmall well volume (25 µL) for conserving samples or re-
GOptical grade bottom cover glass that allows measure-
GAlphanumeric grid for easy sample identification
GBackground fluorescence is minimized by the glass
GSuitable for fluorescence correlation spectroscopy (FCS)
NOTE: * Max. autoclaving cycle: 3 times (121 °C, 103 kPa, 20 minutes)
Material
Number of wells
Recommended working volume
Well diameter
Well depth
Cover glass thickness
Refractive index of cover glass
Dimensions
Sterile
Package
agents
ment with an inverted microscope
R1.0
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2009 Hamamatsu Photonics K.K.
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
FEATURES
SPECIFICATIONS
DIMENSIONAL OUTLINE
R1.0
Parameter
2.0
Slide glass
Cover glass
3.0
A
B
C
4.0
1
2
P5.0 × 6=30.0
3
57.2
50.0
4
57.2 mm × 25.4 mm × 3.4 mm
5
4 mm (top), 3 mm (bottom)
0.12 mm to 0.17 mm
6
Description / Value
Borosilicate glass
Soda-lime glass
7
Untreated *
21 (3 × 7)
COVER GLASS
10 slides
3.1 mm
25 µL
1.525
(Unit: mm)
3-R1.0
TOTHA0003EA
MICROWELL SLIDE
A10657-01
Notes:
Sonication should be limited to one time only. (Sonica-
tion time cannot exceed 15 minutes.)
Please handle with care when cleaning the microwell
slide in a beaker or some other glass container, as
cracks may form on the microwell slide upon contact
with a glass surface.
APPLICATION EXAMPLES
GFCS unit C9413 series
GInverted microscope

Related parts for a10657-01

a10657-01 Summary of contents

Page 1

... Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2009 Hamamatsu Photonics K.K. MICROWELL SLIDE A10657-01 Description / Value Soda-lime glass Borosilicate glass 21 (3 × ...

Page 2

... MICROWELL SLIDE A10657-01 MEASUREMENT EXAMPLES IMeasurement example 1: EGFP expressing and non-expressing HeLa cell stained with MitoTracker Deep Red 633 FM IMeasurement example 2: FCS measurement in HeLa cell 5 4 1.010 1.005 1.000 10 0 Courtesy of Mr. Keishi Sakata, Ms. Makiyo Uchida, Prof. Masataka Kinjo, Laboratory of Molecular Cell Dynamics, Faculty of Advanced Life Science, Graduate School of Life Science, Hokkaido University HAMAMATSU PHOTONICS K ...

Related keywords